Photo of 6.3kW ECONAVI Reverse Cycle Inverter Air Conditioner

6.3kW ECONAVI Reverse Cycle Inverter Air Conditioner

General Indoor Unit CS-E21PKR
Outdoor Unit CU-E21PKR
Function Cooling + Heating
PERFORMANCE Cooling Capacity Rated Conditions (kW) 6.3
Cooling Capacity Range - Min ~ Max (kW) 1.70 ~ 7.10
EER (w/w) 3.5
Heating Capacity Rated Conditions (kW) 7.2
Heating Capacity Range - Min ~ Max (kW) 1.70 ~ 8.50
COP (w/w) 3.64
Star Rating - Cool / Heat 2.0 / 2.0
SPECIFICATIONS Electrical Voltage (V) 240
Running Current - Cool / Heat (A) 8.4 / 8.5
Power Input - Cool / Heat (kW) 1.80 / 1.98
Sound Pressure Indoor - Cool - Hi / Lo / S-Lo (dB(A)) 47 / 36 / 33
Sound Pressure Indoor - Heat - Hi / Lo / S-Lo (dB(A)) 47 / 35 / 32
Sound Pressure Outdoor - Cool - Hi / S-Lo (dB(A)) 53 / 48
Sound Pressure Outdoor - Heat - Hi / S-Lo (dB(A)) 53 / 48
Sound Power Outdoor - Cool - Hi / S-Lo (dB) 67 / 62
Sound Power Outdoor - Heat - Hi / S-Lo (dB) 67 / 62
Quiet Mode - Indoor (dB) 33
Quiet Mode - Outdoor (dB) 48
Dehumidify (L/h) 3.5
Air Flow - Cool / Heat (L/s) 288 / 277
Indoor Dimensions - H x W x D (mm) 290 x 1070 x 240
Outdoor Dimensions - H x W x D (mm) 795 x 875 x 320
Weight - Indoor (kg) 12
Weight - Outdoor (kg) 59
Refrigerant Pipe Diameter - Liquid Side / Gas Side (mm) 6.35 / 12.70
Piping Extension Length Min ~ Max (m) 3 ~ 20
Pipe Length for Additional Gas (m) 10
Additional Refrigerant (R410A) (g/m) 20
Power Supply Outdoor
Operating Temperature Range - Outdoor - Cooling (˚C) 5 ~ 46
Operating Temperature Range - Outdoor - Heating (˚C) -15 ~ 24
Warranty - Residential 5 Years Manufacturer's Warranty
FEATURES - Healthier Air Nonoe-g Air Purifying System Yes
Anti Bacterial Air Filter -
Odour Removing Function Yes
Removable, Washable Panel Yes
FEATURES - Comfort ECONAVI Yes
AUTOCOMFORT Yes
Inverter Control Yes
Mild Dry Cooling Yes
Powerful Mode Yes
Economy Mode -
Heating Operation Lower Limit (o C) -15
Cooling Operation Higher Limit (o C) 46
Soft Dry Operation Mode Yes
Fan Mode Yes
Remote Airflow Control (All directions) Yes
Remote Airflow control (Up & Down) -
Manual Horizontal Airflow Direction Control -
Auto Changeover - Inverter Yes
Automatic Operation Mode -
Hot Start Control Yes
FEATURES - Convenience 24-hour Dual On / Off Real Setting Timer Yes
12-hour On / Off Timer -
Demand Response Compatible Yes
3rd Party Connectivity Yes
LCD Wireless Remote Controller Large
Wired Remote Controller Optional
FEATURES - Reliability Blue Fin Condenser Yes
Random Auto Restart Yes
Long Piping (m) 20
Top-panel Maintenance Access Yes
Self Diagnostic Function Yes