2-Pipe Mini-FSV LE Series

2-Pipe Mini-FSV LE Series

· High external static pressure 35 Pa
· Wide operation range: Cooling: -10°C to 46°C DB, Heating at: -20°C to 18°C WB
· Refrigerant chargeless up to 50 m (LE2)
· Diversity ratio 50-130%
· Actual piping length: 150 m (total piping length: 300 m (LE1) / 180 m (LE2))
· System difference of elevation: 50 m (outdoor unit above) / 40 m (below)

Line Up

Cooling/Heating kW (rated)

12.1/12.5

12.1/12.5

14.0/16.0

14.0/16.0

15.5/16.5

15.5/16.5

22.4/25.0

25.0/28.0

Cooling/Heating Btu/h (rated)

41,300/42,700

41,300/42,700

47,800/54,600

47,800/54,600

52,900/56,300

52,900/56,300

76,500/85,300

85,300/95,600

Model No.

U-4LE2R5

U-4LE2R8

U-5LE2R5

U-5LE2R8

U-6LE2R5

U-6LE2R8

U-8LE1R8

U-10LE1R8

Features

Extraordinary Energy-Saving Performance

The operation efficiency has been improved using a highly efficient R410A refrigerant, a DC Inverter compressor, a DC motor, and a heat exchanger design.

Energy Savings Design

1. Panasonic’s inverter compressor to improve partial-load capacity.
2. 2 pieces of the printed circuit board for easy maintenance.
3. Large-size accumulator to maintain compressor reliability for extended max piping length.
4. DC fan motor for optimum air volume.
5. Newly designed fan blades to inhibit air turbulence and increase efficiency.
6. Redesigned heat exchanger & copper tubes to increase efficiency.
7. Centrifugal oil separator improves oil separation efficiency and reduces refrigerant pressure loss.

Variable Evaporation Temperature (VET) for Energy Saving and Comfortable Air conditioning

The indoor and outdoor units work in tandem to control evaporation temperature, refrigerant volume, and airflow. This enables optimal air conditioning according to the number of people in the room and the indoor temperature, as well as energy savings and comfort.

 

Note: When fan speed is set to Auto.

Demand Response Ready

Simple Demand Response

Featuring inverter control technology, LE1, LE2 series systems are Demand Response Management (DRM) ready. With this control, power consumption at times of peak load can be set in three steps to deliver optimum performance. This helps to correspond with the local power management for reducing peak power consumption, and to reduce annual power consumption with minimal loss in comfort.

 

*Demand controller. Relay contact point: No voltage relay.
**Current input is DC 24V 10mA Use a very small electric current contact point for the relay.

Flexible Demand Response

A maintenance remote controller for service and special connection wiring are required for setting up the outdoor unit after installation of the kit, please contact your dealer for details.

High Durability

Wide Operating Range

Cooling operation is possible even when the outdoor temperature is as low as -10°C DB or as high as 46°C DB. As for heating operation, it is possible even when the outdoor temperature is as low as -20°C WB. The remote controller temperature can be set from 18°C up to 30°C (cooling), 16°C up to 30°C (heating)*.

 

*Depending on the type of remote controller.
Note: Cooling/heating capacity depend on indoor/outdoor temperature. Please refer technical databook.

Rust-resistant and Easy to Maintain

Corrosion-resistance treated for exposure to rust to assure long-lasting performance. The anti-corrosion Blue Fin treatment of the heat exchanger provides greater resistance against corrosion. Specific models with suffix “E” have this treatment. (Blue Fin treatment is applied to the condenser of the heat exchanger on all models.) Panasonic also uses a copper tube condenser, which makes it easy to repair and maintain.

 

Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.

Smart Power Saving with IoT

Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

CONEX goes beyond simple remote control to combine sophistication with simplicity, offering IoT integration that connects directly to a variety of apps for next-generation solutions.

 

Note: A wireless remote controller is provided with the product.

Smart Management of Power Consumption

Using the Panasonic Comfort Cloud app enables the air conditioner to be controlled from anywhere with a mobile device. Thus, there is no need to worry if someone forgets to turn off the office air conditioner. The power consumption can also be monitored to help reduce electricity waste.

 

Note: CZ-CAPWFC2 External WLAN Adaptor or CZ-RTC6WBLW2/6BLW2 are required per unit.

Highly Flexible Installation and Design

・ Maximum total piping length 180 m (4/5/6 HP) / 300 m (8/10 HP).
・ Actual piping length 150 m.
・ Elevation difference of maximum 50 m in case of outdoor unit is higher than indoor unit.
・ Maximum 15 meters height difference between indoor units.
・ Up to 50 m of piping without additional gas charging (4/5/6 HP).
・ Up to 13 indoor units connectable in case of 8/10 HP.
・ High external static pressure of 35 Pa.

Talk to Our Air Design Specialists

We’ll help you choose exactly the right applications and products.

Find Your Nearest Dealers

Contact Us

Case Studies

Panasonic supplies and installs a wide range of products in various types of residential and commercial buildings such as shops, restaurants, hotels, offices, clinics, and public buildings,  helping create cleaner and more comfortable environments all over the world.