E2 Type High Static Ducted/High Fresh Air Ducted
NO ROOM TO ADD MORE PRODUCTS
The wishlist has already reached the maximum number of products
E2 Type High Static Ducted/High Fresh Air Ducted
High static and large airflow ducted with fresh air intake



Features
Cooling/Heating kW (rated) |
18.0/20.0 |
22.4/25.0 |
28.0/31.5 |
Cooling/Heating Btu/h (rated) |
61,400/68,200 |
76,400/85,300 |
95,500/107,500 |
Model No. |
S-180ME2E5* |
S-224ME2E5 |
S-280ME2E5 |
![]() |
![]() |
![]() |
Fresh Air Intake Possible

Mix Operation Unit with Standard Indoor Units

Selectable Static Pressure for Installation Flexibility
3-Step Static Pressure Set Up

Max. 270 Pa Static Pressure Setting for Large Facilities

Installation of Inspection Port Necessary

Optional Parts for High Static Ducted Series
Model Indoor Unit |
Model Outdoor Unit |
Operation |
RAP Valve Kit |
3-Way Control PCB |
3-Way Valve Kit |
3-Way Valve Kit |
Distribution Joint Kit |
Distribution Joint Kit |
|
CZ-P160RVK2 ![]() |
CZ-CAPE2 ![]() |
CZ-P160HR3 ![]() |
CZ-P4160HR3 |
Solenoid Valve Relay Kit |
CZ-P160BK2
CZ-P680BK2 |
CZ-P224BH2
CZ-P680BH2 |
|||
E2 Type |
2-Way ME1, ME2, MS3 |
Cooling Only |
- |
- |
- |
- |
- |
- |
- |
2-Way ME1&ME2 |
Cooling or Heating |
- |
- |
- |
- |
- |
- |
- |
|
3-Way MF2&MF3 |
Heat Recovery (Simultaneous) |
- |
2 pcs |
2 pcs |
- |
- |
1 pc |
1 pc |
|
- |
- |
- |
use 2 ports (160 x 2) |
use 1 pc |
1 pc |
- |
|||
E2 Type |
2-Way ME1, ME2, MS3 |
Cooling Only |
- |
- |
- |
- |
- |
- |
- |
2-Way ME1&ME2 |
Cooling or Heating |
2 pcs |
2 pcs |
- |
- |
- |
2 pcs |
- |
|
3-Way MF2&MF3 |
Heat Recovery (Simultaneous) |
- |
2 pcs |
2 pcs |
- |
- |
1 pc |
1 pc |
|
- |
- |
- |
use 2 ports (160 x 2) |
use 1 pc |
1 pc |
- |
Smart Power Saving with IoT
Next-Generation Remote Control Solution Optimised for Usability, Whatever Your Needs

Smart Management of Power Consumption
Using the Panasonic Comfort Cloud app enables the air conditioner to be controlled from anywhere with a mobile device. Thus, there is no need to worry if someone forgets to turn off the office air conditioner. The power consumption can also be monitored to help reduce electricity waste.
Note: CZ-CAPWFC1 External WLAN Adaptor is required per unit.

Leading Control Options

Specs
R410A
High Fresh Air
DC motor
Design flexibility thanks to high static pressure and large air volume
Power input 45% less (High Static Ducted type, compared to E1 type)
Power input 45% less (High Fresh Air Ducted type, compared to H1 type)
Discharge air temperature control to reduce cold drafts during heating operation
Configurable air temperature control
100% fresh air intake for ventilation purposes (except for S-180ME2E5)