Model (50Hz) |
CS-A18PKD (CU-A18PKD) |
Cooling/ Heating Capacity |
Btu/h |
18,100 - 18,100 19,300 - 19,400 |
kW |
5.30 - 5.30 5.65 - 5.70 |
EER/ COP |
Btu/hW |
10.52 - 10.28 11.70 - 11.35 |
Electrical Data |
Voltage |
V |
220 - 230 |
Running Current |
A |
8.0 - 7.8 7.7 - 7.6 |
Power Input |
W |
1,720 - 1,760 1,650 - 1,710 |
Moisture Removal |
L/h |
2.9 |
Pt/h |
6.1 |
Air Circulation (Indoor/Hi) |
m³/min. |
16.4 17.1 |
ft³/min. |
579 604 |
Dimensions |
Height |
mm |
290 (695) |
inch |
11-7/16 (27-3/8) |
Width |
mm |
1,070 (875) |
inch |
42-5/32 (34-15/32) |
Depth |
mm |
240 (320) |
inch |
9-15/32 (12-5/8) |
Net Weight |
kg |
12 (55) |
lb |
26 (121) |
Refrigerant Pipe Diameter |
Liquid Side |
mm / inch |
ø 6.35 / 1/4 |
Gas Side |
mm / inch |
ø 12.70 / 1/2 |
Pipe Extension |
Chargeless Pipe Length |
m |
7.5 |
Maximum Pipe Length |
m |
25 |
Maximum Elevation Length |
m |
20 |
Additional Refrigerant Gas* |
g/m |
20 |
Power Supply |
Indoor |
NOTE |
* When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit. |