Cooling/Heating kW (rated)

2.2/2.5

2.8/3.2

3.6/4.2

4.5/5.0

5.6/6.3

Cooling/Heating Btu/h (rated)

7,500/8,500

9,600/10,900

12,300/14,300

15,400/17,100

19,100/21,500

Model No.

S-22MY2E5A

S-28MY2E5A

S-36MY2E5A

S-45MY2E5A

S-56MY2E5A

Cools All Areas Quickly

Powerful airflow delivered from all four sides of the unit instantly transforms all areas of spaces into a comfortable and cool environment.
Note: This table shows values for the airflow rate in high mode.
Cools All Areas Quickly

Flat Horizontal Design That Conditions the Interior

Panasonic believes that one of the most important elements of design is that it doesn’t interfere with the overall room interior. The flat horizontal design of the 4-Way Mini Cassette achieves an elegant yet simple form. This design allows it to protrude only 31 mm from the ceiling, to blend naturally into a variety of interiors, including offices and restaurants.
Flat Horizontal Design That Conditions the Interior

ECONAVI Sensor

Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.

1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximise the energy-saving effect.
ECONAVI Sensor

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Flexible Installation

Thanks to advanced Panasonic design, the panel is a compact 700 x 700 mm, offering elegant, unobtrusive installation even where space is limited.
Compact Design

When only 260 mm of indoor body height, it can easily fit in limited spaces and tight spots. (Required 288 mm from bottom of panel to top of the unit)
Lighter and Slimmer, Easier Installation

The internal pump allows the drain pipe to be elevated up to 750 mm from the lower surface of the body.
A Drain Height of Up to 750 mm from the Ceiling Surface

Specs

S-22MY2E5A

Photo of S-22MY2E5A

S-28MY2E5A

Photo of S-28MY2E5A

S-36MY2E5A

Photo of S-36MY2E5A

S-45MY2E5A

Photo of S-45MY2E5A

S-56MY2E5A

Photo of S-56MY2E5A
  • ECONAVIECONAVI
  • R410AR410A
  • DC motorDC motor

Mini cassette fits into a 60 x 60 cm ceiling grid

Powerful drain pump gives 750 mm lift

DC fan motor with variable speed and a new heat exchanger ensures efficient power consumption

Fresh air knock out

Multi-directional airflow

S-22MY2E5A S-28MY2E5A S-36MY2E5A S-45MY2E5A S-56MY2E5A
Power Source 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz
Cooling Capacity 2.2 kW, 7,500 Btu/h 2.8 kW, 9,600 Btu/h 3.6 kW, 12,300 Btu/h 4.5 kW, 15,400 Btu/h 5.6 kW, 19,100 Btu/h
Heating Capacity 2.5 kW, 8,500 Btu/h 3.2 kW, 10,900 Btu/h 4.2 kW, 14,300 Btu/h 5.0 kW, 17,100 Btu/h 6.3 kW, 21,500 Btu/h
Power Input (Cooling) 0.035 kW 0.035 kW 0.040 kW 0.040 kW 0.045 kW
Power Input (Heating) 0.030 kW 0.030 kW 0.035 kW 0.035 kW 0.040 kW
Running Current (Cooling) 0.30 A 0.30 A 0.27/0.26/0.25 A 0.32 A 0.35 A
Running Current (Heating) 0.25 A 0.30 A 0.24/0.23/0.22 A 0.30 A 0.35 A
Fan Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Air Flow Rate (H/M/L) 546/492/336 m³/h, 152/137/93 L/s 558/504/336 m³/h, 155/140/93 L/s 582/522/360 m³/h, 162/145/100 L/s 600/558/492 m³/h, 167/155/137 L/s 624/588/510 m³/h, 173/163/142 L/s
Fan Motor Output 0.04 kW 0.04 kW 0.04 kW 0.04 kW 0.04 kW
Sound Power Level (Cooling) (H/M/L) 50/46/40 dB 50/46/40 dB 51/47/41 dB 53/49/43 dB 55/52/49 dB
Sound Power Level (Heating) (H/M/L) 50/46/40 dB 50/46/40 dB 51/47/41 dB 53/49/43 dB 55/52/49 dB
Sound Pressure Level (Cooling) (H/M/L) 35/31/25 dB (A) 35/31/25 dB (A) 36/32/26 dB (A) 38/34/28 dB (A) 40/37/34 dB (A)
Sound Pressure Level (Heating) (H/M/L) 35/31/25 dB (A) 35/31/25 dB (A) 36/32/26 dB (A) 38/34/28 dB (A) 40/37/34 dB (A)
Dimension H288 x W575 x D575 mm H288 x W575 x D575 mm H288 x W575 x D575 mm H288 x W575 x D575 mm H288 x W575 x D575 mm
Dimension with the Optional Ceiling Panel H319 x W700 x D700 mm H319 x W700 x D700 mm H319 x W700 x D700 mm H319 x W700 x D700 mm H319 x W700 x D700 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch)
Pipe Connection (Drain Piping) VP-25 VP-25 VP-25 VP-25 VP-25
Net Weight 18 kg 18 kg 18 kg 18 kg 18 kg
Net Weight with the Optional Ceiling Panel 20.4 kg 20.4 kg 20.4 kg 20.4 kg 20.4 kg