S$ #,###.00 000 010 //panasonic-singapore.ibrandiq.com/en/Widgets/Fluid/{0} //panasonic-singapore.ibrandiq.com/Products/MultipleInStock/Fluid/{0}
Photo of CS-PU12WKZ
MODEL (50Hz) CS-PU12WKZ
[CU-PU12WKZ]
Cooling Capacity (min-max) kW 3.50 (1.02-4.00)
Btu/h 11,900 (3,480-13,600)
Weighted COP W/W 4.30
COP / EER (min-max) W/W 3.57 (3.71-3.25)
Btu/hW 12.14 (12.65-11.06)
Electrical Data Voltage V 220-240
Current A 4.5-4.2
Power Input (min-max) W 980 (275-1,230)
Moisture Removal L/h 2.0
Pt/h 4.2
Air Circulation Indoor m³/min (ft³/min) 11.3 (400)
Outdoor m³/min (ft³/min) 30.6 (1,080)-30.6 (1,080)
Noise Level (220V-240V) Indoor (H / L/ Q-Lo) dB(A) 38/28/21
Outdoor (H) dB(A) 48-48
Dimensions Indoor (Outdoor) Height mm 290 (542)
inch 11-7/16 (21-11/32)
Width mm 779 (780)
inch 30-11/16 (30-23/32)
Depth mm 209 (289)
inch 8-1/4 (11-13/32)
Net Weight Indoor kg (lb) 8 (18)
Outdoor kg (lb) 23 (51)
Refrigerant Pipe Diameter Liquid Side mm ø 6.35
inch 1/4
Gas Side mm ø 9.52
inch 3/8
Pipe Extension Chargeless Pipe Length m 7.5
Maximum Pipe Length m 20
Maximum Elevation Length m 15
Additional Refrigerant Gas* g/m 10
Power Supply Outdoor
NOTE * When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.