Non-Inverter Ceiling Ducted
Ceiling-ducted units are suitable for premises with concealed or false ceilings such as business centres. They offer remarkable overall cooling coverage of the entire building.

Document
Features
Easy Installation, Maintenance, and Cleaning
The unit has a height of only 290mm, so it allows installation in limited ceiling spaces. The lightweight, attractive design simplifies installation,and matches virtually all room interiors. Maintenance works can be done from the underside of the indoor unit.
Supports for
S-22PF1H5
S-28PF1H5

Wired Remote Controller
Precise Control, Easy Comfort
Panasonic Packaged Series Remote Controllers are designed with user convenience in mind. Multiple settings are available, so airflow and air quality can be regulated according to user preferences.

Group Control with a Single Remote Controller
• All indoor units operate in the same mode.

Separate Control with Twin Remote Controllers
• Each indoor unit can be operated by either of the two remote controllers.
• Apart from the timer setting time, the displays for the two remote controllers are identical.
• The last button pressed has priority (The main or slave attribute is set with the remote controller).

Weekly Timer
1.Select Day
Timer can be set for each day of the week.
2.Enter Time
Can be pre-set with: Max.6 settings/day, 42 settings/week.
3. Set Temperature
The temperature can also be programmed for optimal comfort.

Odour Wash
Reduces unpleasant odours caused by the air conditioner’s heat exchanger.
When air from the outlet smells musty, moisture in the heat exchanger washes away odours. Can be operated with the wireless remote controller.

Economy Mode
Saves up to 20%* energy. The air conditioner determines the stable condition and moderately shifts the set temperature in 0.5-degree steps to regulate the energy-saving operation (maximum 2 degrees).
*When operating in cooling mode at 25°C or lower.

Ventilation
When an external device such as a ventilator is connected to the indoor unit, the ventilator’s on/off operations can be controlled by the wired remote controller. You can select from either linked ventilation or independent ventilation.
Note: Ventilators are not included in the product line-up. Printed circuit board (Interface Adapter for External Signals CZ-TA31P) is required .
*Printed Circuit Board CZ-TA31P
•By connecting to the indoor unit, a separately sold ventilator can be controlled.
•Remote operation control of the indoor unit is enabled (ON/OFF control).
•The condition of the indoor unit (malfunctions operating status) can be output externally.
•Control in linkage to a total heat exchanger or similar devices is possible.

Central Control Adapter
Using the Central Control Adapter along with existing VRF units, a centralized control system can be created to manage temperature in small and mid-sized buildings.

Why Panasonic
Talk to our Air Design Specialists