X-Premium Inverter Single Split with nanoe™ X - ZZP-SG0101A

Photo of X-Premium Inverter Single Split with nanoe™ X - ZZP-SG0101A

Model name

  • ZZP-SG0101A

Indoor Unit

  • CS-XU9BKZW

Outdoor Unit

  • CU-XU9BKZ

Cooling Capacity (min-max) (kW)

  • 2.50 (1.30-3.60) kW

Cooling Capacity (min-max) (Btu/h)

  • 8,530 (4,430-12,300) Btu/h

COP (min-max) (W/W)

  • 4.20 (7.03-3.30) W/W

EER (min-max) (Btu/hW)

  • 14.34 (23.95-11.28) Btu/hW

Weighted COP (W/W)

  • 5.65 W/W

Voltage (V)

  • 220-240 V

Current (A)

  • 2.8-2.6 A

Power Input (min-max) (W)

  • 595 (185-1,090) W

Moisture Removal (L/h)

  • 1.5 L/h

Moisture Removal (Pt/h)

  • 3.2 Pt/h

Indoor Unit Air Circulation

  • 12.0 m³/min (425 ft³/min)

Indoor Unit Noise Level (H / L / Q-Lo)

  • 42/26/19 dB(A)

Indoor Unit Dimensions (H x W x D) (mm)

  • 295 mm x 890 mm x 244 mm

Indoor Unit Dimensions (H x W x D) (inch)

  • 11-5/8 inch x 35-1/16 inch x 9-5/8 inch

Indoor Unit Net Weight

  • 10 kg (22 lb)

Outdoor Unit Air Circulation

  • 30.0 m³/min (1,060 ft³/min)

Outdoor Unit Noise Level (H)

  • 47 dB(A)

Outdoor Unit Dimensions (H x W x D) (mm)

  • 542 mm x 780 mm x 289 mm

Outdoor Unit Dimensions (H x W x D) (inch)

  • 21-11/32 inch x 30-23/32 inch x 11-13/32 inch

Outdoor Unit Net Weight

  • 23 kg (51 lb)

Refrigerant Pipe Diameter (Liquid Side)

  • ø 6.35 mm (1/4 inch)

Refrigerant Pipe Diameter (Gas Side)

  • ø 9.52 mm (3/8 inch)

Pipe Extension (Chargeless Pipe Length)

  • 7.5 m

Pipe Extension (Maximum Pipe Length)

  • 20 m

Pipe Extension (Maximum Elevation Length)

  • 15 m

Pipe Extension (Additional Refrigerant Gas*)

  • 10 g/m
    *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

Power Supply

  • Outdoor

nanoe™ X

  • Yes (Generator Mark 3)

nanoe-G

  • Yes

Inside Cleaning on Demand

  • Yes

Odour Removing Function

  • Yes

Removable Washable Panel

  • Yes

Wi-Fi

  • Yes (Built-in)

24-Hour Dual ON & OFF Real Setting Timer

  • Yes

LCD Wireless Remote Control

  • Yes

Wired Remote Control

  • Yes (Optional)

iAUTO-X

  • Yes

Humidity Sensor

  • Yes

Sleep Mode

  • Yes

Quiet Mode

  • Yes

Soft Dry Operation Mode

  • Yes

Personal Airflow Creation

  • Yes

Inverter Control

  • Yes

Eco Mode with A.I.

  • Yes

Random Auto Restart

  • Yes (32 Restart Patterns)

Blue Fin Condenser

  • Yes

Long Piping (max.)

  • 20 m

Top Panel Maintenance Access

  • Yes

Self-Diagnostic Function

  • Yes

Note