Ultra Filtration Alkaline Ionizer TK-AS700-WEX

Photo of Ultra Filtration Alkaline Ionizer TK-AS700-WEX

Rated voltage, frequency, input current

  • 220-240 V ~ , 50 Hz, 0.65 A

Rated power consumption

  • Approx. 130 W (approx. 1 W during standby)

Main unit

  • Dimensions

    • Approx. 180(W) × 115(D) × 328(H) mm(Depth including LCD display: 123 mm)
  • Weight

    • Approx. 3.8 kg (approx. 4.3 kg when full of water)

Temperature of water used by Alkaline Ionizer

  • Under 35 °C (under 80 °C for bypass selector)

Pressure of water used by Alkaline Ionizer (dynamic pressure)

  • 70 kPa to 350 kPa

Usable water service pressure (static pressure)

  • 70 kPa to 750 kPa

Electrolysis

  • Electrolysis method

    • Continuous electrolysis
  • Output water volume (flow of water produced)

    • Alkaline water : 1.5 L/min. [at 100 kPa water pressure] (“Standard” mode)Weak acidic water : 1.3 L/min. [at 100 kPa water pressure]
  • Electrolysis capability selection

    • Alkaline: 4 levels; weak acidic: 2 levels
  • Continuous operation capability

    • Approx. 10 minutes at room temperature (Note 1)
  • Electrolyzer life

    • Approx. 850 hours cumulative(ion water production time, cleaning time only)
  • Electrolytic cleaning

    • Auto cleaning method

Purified water output volume

  • 1.6 L/min. [at 100 kPa water pressure]

Filtration flow volume

  • 1.6 L/min. [at 100 kPa water pressure] (Note 2)

Cartridge Installed In the unit

  • TK-AS700C-EX

Purification capacity

  • Free residual chlorine

    • 6000 L (Note 2,3)
  • Turbidity

    • 6000 L (Note 2, 4)
  • Chloroform

    • 6000 L (Note 2, 5)
  • Total trihalomethane

    • 6000 L (Note 2, 5)
  • Bromodichloromethane

    • 6000 L (Note 2, 5)
  • Dibromochloromethane

    • 6000 L (Note 2, 5)
  • Bromoform

    • 6000 L (Note 2, 5)
  • Tetrachloroethylene

    • 6000 L (Note 2, 5)
  • Trichloroethylene

    • 6000 L (Note 2, 5)
  • CAT (pesticide)

    • 6000 L (Note 2, 3)
  • 2-MIB (mold smell)

    • 6000 L (Note 2, 3)
  • Soluble lead

    • 6000 L (Note 2, 3)
  • 1,2-DCE

    • 6000 L (Note 2, 5)
  • Benzene

    • 6000 L (Note 2, 5)
  • Geosmin (mold smell)

    • 6000 L (Note 2, 3)
  • Phenols

    • 6000 L (Note 2, 3)
  • Carbon tetrachloride

    • 6000 L (Note 2, 6)

Removable substances

  • Iron (particulate form)

    • Can be removed (Note 7)
  • Aluminium (neutral)

    • Can be removed (Note 7)

Guide for time to replace cartridge

  • Approx. 1 year (Note 8)

Filter material

  • Non-woven fabric, ceramic, activated carbon, hollow fiber membrane

Components which cannot be filtered out

  • Iron dissolved in water, heavy metals (silver, copper, etc.), salt (seawater)

Length of power cord

  • Approx. 3 m

Power protection device

  • Current fuse: 2.5 A

Note

  • * All figures given are for a water temperature of 20 °C.* This product cannot convert hard water into soft water.* The total volume of water coming out of the main spout, drain hose is given as the run through water volume and daily volume of water used.* Activated carbon uses powdered activated carbon and granular activated carbon.(Note1) This period may be shorter depending on the water quality and usage environment.(Note2) The amount of water that can be used with Alkaline 1 to 3 in Standard Milder mode is equivalent to about 94 % of the filtration flow volume (water purifying capacity).(Note3) This value is for a removal rate of 80 % based on JIS S 3201 tests.(Note4) This value is for a filtration flow volume of 50 % based on JIS S 3201 tests.(Note5) This value is for a removal rate of 80 % based on JIS S 3201 Annex A tests.(Note6) This value is for a removal rate of 80 % based on specifi cation standard tests (JWPAS B standards) stipulated by the Japan Water Purifi er Association (JWPA).(Note7) This substance is for a removal rate of 80 % based on specification standard tests (JWPAS B standards) stipulated by the Japan Water Purifier Association (JWPA). Note that it is not stipulated as part of purification capacity.(Note8) This period applies when 15 liters of water are used a day. If 30 liters are used a day, the cartridge usage limit will be approximately one-half.The period may also be signifi cantly less depending on the amount of water used and on its quality and pressure.