Simulation Conditions
![]() ![]() |
Facility type : |
Clinic |
Target area : |
162.9m² |
|
Space height : |
2.7m |
|
Type of indoor unit and nanoe™ generator : |
4-way Cassette |
|
Type of outdoor unit : |
VRF |
|
Ventilation unit : |
ERV |
|
Average nanoe™ concentration level (120 minutes later) : |
Level 2 |
nanoe™ distribution and concentration level over time
There are 7 key benefits provided by nanoe™ which commence when concentration reaches Level 1.
The concentration level affects the speed at which the benefits occur.Concentration level 2 is 10 times the concentration of level 1, and concentration level 3 is 20 times the concentration of level 1.
*The results shown are for simulation purpose only and concentration may vary due to actual room conditions.


Exaust Air (EA)

Supply Air (SA)
1 minute later

10 minutes later

120 minutes later

Room Conditions
Office: 17.6㎡
Consultation room 1: 12.4㎡
Consultation room 2 + corridor: 19.6㎡
Procedure room: 13.3㎡
X-ray room: 11.5㎡
Front desk + waiting area: 58.9㎡
Rehabilitation room: 29.6㎡
• Type of indoor unit : 4-way Cassette, Wall-mounted
• Position of indoor unit or air outlet : As indicated in the image
• Ventilation
Position of air inlet/outlet : As indicated in the image
Amount of ventilation : Adequate ventilation level with reference to ASHRAE standards and guidelines
Other Conditions
Amount of generated nanoe: 9.6 trillion / second (Mark2)
Half-life of hydroxyl radical: Approximately 10 minutes
Simulation method: Fluid/concentration diffusional analysis by finite volume method
Remarks
The concentration level of nanoe™ is stabilized after a certain period of time time. This result shows the variability of nanoe™ diffusion at the 3 time points until when nanoe™ concentration is stabilized.
The diffusion of nanoe™ is not effected by the operation mode (heating, cooling, nanoe™, etc.) of the air conditioner.
Simulation was conducted as an independent space by dividing one home into individual room.
nanoe™ particles are extremely tiny in nano-meter size. They cannot be seen so the concentration image is solely for illustrative purposes.
Installation Plan

1. 4-way cassette 2. Wall-mounted 3. ERV
4. Ventilation Fan 5. VRF Outdoor Unit
• Product availability may vary depending on the sales area.
• We can also offer product configurations tailored to the region that provide equivalent performance. Please consult your local dealer.

Concentration level of nanoe™ X is the key for effectiveness
7 Effects nanoe™ X

Known as nature’s detergent, hydroxyl radicals (also known as OH radicals) are natural reactive molecules looking to react with other elements such as hydrogen. This reaction enables hydroxyl radicals to inhibit the growth of pollutants. Panasonic’s nanoe™ X technology brings these effects to purify surfaces and indoor environments.
The concentration level of nanoe™ X is the key to effectiveness. The higher the concentration, the more hydroxyl radicals are in the space, and the quicker the effect can be realized.
This will enable you to enjoy a pleasant and comfortable living space.
Level 1 : Effects expected at concentration Level 1
Adhered virus

(1) Testing organization: Japan Food Research Laboratories
(2) Test subject: Adhered bacteriophage Φ x 174
(3) Test volume: Approx. 25 m³ laboratory (3.3 x 3.5 x 2.2m)
(4) Test result: Inhibited 99.8% in 8 hours
(5) Report No.: 13001265005-01
Airborne virus

(1) Testing organization: Kitasato Research Center for Environmental Science
(2) Test subject: Airborne bacteriophage 174
(3) Test volume: Approx. 25 m³ laboratory (3.5 x 3.3 x 2.2m)
(4) Test result: Inhibited 99.74% in 6 hours
(5) Report No.: 24_0300_1
Bacteria

(1) Testing organization: Japan Food Research Laboratories
(2) Test subject: Adhered staphylococcus aureus
(3) Test volume: Approx. 23 m³ laboratory (3.6 x 2.7 x 2.4m)
(4) Test result: Inhibited 99.1% in 8 hours
(5) Report No.: 13044083003-01
Mold

(1) Testing organization: Japan Food Research Laboratories
(2) Test subject: Airborne cladsporium
(3) Test volume: Approx. 23 m³ laboratory (3.6 x 2.7 x 2.4m)
(4) Test result: Inhibited 99% in 1 hour
(5) Report No.: 205061541-001
Level 2 : Effects expected at concentration Level 2
Level 2 is 10 times more concentrated than Level 1, and compared to Level 1 takes less time to realize the effects.
Pollen

After 8 hours
(1) Testing organization: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test result: Inhibited over 88% in 8 hours
(5) Report No.: BAA33-130402-F0
After 24 hours
(1) Testing organization: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 24 hours
(5) Report No.: 4AA33-151001-F01
Level 3 : Effects expected at concentration Level 3
Level 3 is 20 times more concentrated than Level 1, and compared to Level 2 takes less time to realize the effects.
Pollen
Time to inhibition of pollen up to 99%

Level 2:
(1) Testing organization: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 24 hours
(5) Report No.: 4AA33-151001-F01
Level 3:
(1) Testing organization: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 12 hours confirmed
(5) Report No.: L19YA009
Age-related body odor
Time to reduce odor intensity by 1.7 levels

Level 2:
(1) Testing organization: Panasonic Product Analysis Center
(2) Target odor: Surface-adhered age-related body odor
(3) Test volume: approximately 23 m³-sized test chamber
(4) Test result: Odor intensity reduced by 1.3 levels in 2 hours
(5) Report No.: Y18HM047-1
Level 3:
(1) Testing organization: Panasonic Product Analysis Center
(2) Target odor: Surface-adhered age-related body odor
(3) Test volume: approximately 23 m³-sized test chamber
(4) Test result: Odor intensity reduced by 1.7 levels in one hour
(5) Report No.: Y18HM059