2-WAY FSV EX ME2 Series
Extraordinary energy-saving performance and powerful operation.

Technical Focus
• Wide range of systems from 8HP to 80HP(ME2 Series Space Saving Combination)
• Wide range of systems from 8HP to 64HP(ME2 Series High Efficiency Combination)
• Class-leading EER of 4.7 (for 8HP model)
• Cooling operation possible with outdoor temperature as high as 52˚C (DB)
• Long maximum pipe length (up to 1,000 m)
• Up to 64 indoor units connectable
Extraordinary Energy-Saving Performance
The FSV-EX marks a revolutionary step forward in VRF efficiency. A look at the incredible EER value clearly indicates that. What’s more, this high EER value is achieved even during part load operation. This shows the extraordinary energy-saving performance the FSV-EX is capable of providing.

Excellent Energy Savings
The operation efficiency has been improved using highly efficient R410A refrigerant, new DC inverter compressor, and new heat exchanger design.


1. Multiple large-capacity all inverter compressors (more than 14HP)
Two independently controlled inverter compressors achieve high efficiency. Redesigned components in the body provide performance improvement especially in the rated cooling condition and EER performance.
2. Enlarged heat exchanger surface area with triple surface*
The new heat exchanger features a triple-surface construction. Compared to the divided dualsurface construction in current models, there is no division of space and the area for heat exchange is larger. Also, highly efficient piping pattern increases heat exchange performance by 5%
* For 8 & 10HP unit, the heat exchanger is 2 row design.

Intelligent 3-Stage Oil Management System
In a VRF system, where lengthy piping and a large number of indoor units need to be controlled collectively, the key to maintaining the system’s reliability is to ensure an appropriate amount of oil is secured in the compressors. In order to avoid oil shortage in the compressor, maximum operation is normally forcibly conducted at regular intervals to recover oil from indoor units. This method, typically employed in a standard VRF, causes the system to overheat or overcool and thus waste energy. In Panasonic VRF systems, a sensor for detecting oil levels is mounted in each compressor. In installations with multiple outdoor units, a shortage of oil in one compressor can be compensated for by recovering oil either from another compressor in the same unit, from a compressor in an adjacent outdoor unit, or from a connected indoor unit. Panasonic VRF systems provide users with a comfortable environment whilst saving energy.

The Panasonic System Efficiently Manages Oil Recovery in Three Stages
Minimising the frequency of forced oil recovery while reducing energy cost and maintaining comfort.

Panasonic compressors are equipped with sensors which monitor oil levels precisely at all times. If oil levels fall, oil can be transferred from other compressors within the same outdoor unit.

If oil levels in all compressors within the outdoor unit fall, oil can be replenished from adjacent outdoor units.

Forced oil recovery is implemented only if oil levels become insufficient in spite of above measures. The Panasonic system’s design concept is radically different from conventional oil systems.
Features of 3-Stage Oil Recovery Design

1. Oil sensors installed in each compressor
Oil sensors installed in each Panasonic compressor precisely monitor oil levels, eliminating unnecessary oil recovery.
2. Highly functional oil separator
Thanks to extended separate piping, oil recovery efficiency reaches 90%, minimising the oil to be discharged from the compressor.
A : Minimum oil level (Surface of rotary cylinder)
B : In Panasonic VRF systems, a sensor for detecting oil levels is installed in each compressor.
Redesigned for Smooth and Better Air Discharge
1. Newly designed curved air discharge bell mouth for better aerodynamics
The new curved shape with integrated top and bottom assure smooth exhaust flow. This gives more air-volume with same sound level, less power input at same air-volume.
2. Large air discharge area with new flush surface top panel
To reduce air resistance, instead of a tubular fan design, a new large flat fan guard design, flush with the top panel, is employed. This design lead to the improvements in air resistance, but also contributed to better appearance designing.

Newly Designed Fan

Optimised air flow
Newly designed fan and bell-mouth reduces stress on the fan by dispersing air quickly. Thus, lower air resistance results in lower energy consumption.

Noise reduction
Turbulence (blue) can be suppressed and the unwanted noise can be reduced. Even though a high speed fan is utilised, the noise level is still very low.
Extended Operation Range Up to 52°C
The FSV-EX can provide cooling even when the outside temperature reaches a maximum of about 52°C. And amazingly, it can still operate at 100% capacity when the outside temperature is as high as 43°C. This high power capability enables reliable operation even under extremely high temperature conditions.

Extended Operating Range
Cooling operation is possible even when outdoor tempature is as low as -10°C DB or as high as 52°C DB. As for heating operation, it is possible even when outdoor temperature as low as -25°C WB. The remote controller temperature can be set from 18°C up to 30°C (Cooling), 16°C up to 30°C (Heating)*.
* Depending on the type of remote controller.

Extended Compressor Life by Uniform Compressor Operation Time
The total run-time of compressors are monitored by a built-in microcomputer, which ensures that operation times of all compressors within the same refrigerant circuit are balanced.
Compressors with histories showing shorter run times are selected first, ensuring equal wear and tear across all units and extended the working life of the system.
* Depend on accumulated operation time of each compressors.
* Compressor priority has possibility to be changed.
(e.g) Case1: AgCgBgD, Case2: CgAgDgB, Case3: AgCgDgB, Case4: CgAgBgD

Automatic Backup Operation
Automatic backup operation works in the case of compressor failure or outdoor unit malfunction.
Even if a whole outdoor unit fails, the other outdoor unit keeps running, and even if a compressor in a single system fails, the other compressor keeps running.
Except for 8, 10 & 12 HP single unit installation
*Backup operation allows uninterrupted cooling or heating to continue whilst waiting for service. Users should contact their authorised service centre as soon as fault occurs.

Flexible Demand Response with the Optional Terminal Block (CZ-CAPDC2)
Featuring inverter control technology, all Panasonic FSV systems are Demand Response Management (DRM) ready. With this control, power consumption at times of peak load can be set in three steps to deliver optimum performance. This helps to reduce annual power consumption with minimal loss in comfort.
Demand control terminal is available to control 0-50-75-100% of capacities.
ME2 series features a DR terminal as standard (not a required option).

Setting is possible as 0% or in the range from 40 to 100% (in steps of 5%). At the time of shipping, setting has been done to the three steps of 0%, 70% and 100%.
*An outdoor Seri-Para l/O unit (CZ-CAPDC2) is required for demand input signal.

Hi-Durability Outdoor Unit
Corrosion-resistance treated for high resistance to rust and salty air to assure long-lasting performance.
Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.

A Large Number of Indoor Units Can Be Connected
Up to 64 indoor units can be connected in a single system for ultimate design flexibility.
*Maximum number of indoor units depends on outdoor unit capacity.

Increased Piping Length for Greater Design Flexibility
Adaptable to various building types and sizes
Actual piping length : 200m
Max piping length : 1,000m
*Elevation difference of Max. 90m in case of ODU is higher than IDU may be allowed following certain conditions. Please consult with Panasonic sales engineers about the certain conditions in case of piping elevation of over 50m is required.
*1: 40 m if the outdoor unit is below the indoor unit.

Up to 50m Length Difference between The Longest and The Shortest Piping From the First Branch
Flexible piping layout makes it easier to design systems for locations such as train stations, airports, schools and hospitals.
• Up to 64 units can be connected to one system.
• Difference between maximum and minimum pipe runs after first branch can be a maximum of 50m.
• Larger pipe runs can be up to 200m.

Connectable Indoor/Outdoor Unit Capacity Ratio Up to 130% *
FSV systems attain maximum indoor unit connection capacity of up to 130 %* of the unit’s connection range, depending on the outdoor and indoor models selected. So for a reasonable investment, FSV systems provide an ideal air conditioning solution for locations where full cooling/heating are not always required.
* If the following conditions are satisfied, the effective range is above 130 % up to 200 %.
I ) Obey the limited number of connectable indoor units.
ii ) The lower limit of operating range for heating outdoor temperature is limited to -10°CWB (standard -25°CWB).
iii ) Simultaneous operation is limited to less than 130 % of connectable indoor units.
System / HP |
8 |
10 |
12 |
14 |
16 |
18 |
20 |
22 |
24 |
26 |
28 |
30 |
32 |
34 |
36 |
38 |
40 |
42 |
44 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MNcIU : 130% |
13 |
16 |
19 |
23 |
26 |
29 |
33 |
36 |
40 |
43 |
46 |
50 |
53 |
56 |
59 |
63 |
64 |
64 |
64 |
System / HP |
46 |
48 |
50 |
52 |
54 |
56 |
58 |
60 |
62 |
64 |
66 |
68 |
70 |
72 |
74 |
76 |
78 |
80 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MNcIU : 130% |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
64 |
MNcIU : Maximum Number of Connectable Indoor Unit
Note: If more than 100% indoor units are operated with a high load, the units may not perform at the rated capacity.
For the details, please consult with an authorised Panasonic dealer
Compact Design
The new ME2 series has reduced the installation space required with up to 20 HP available in a single chassis.
8 - 10 HP are able to fit inside a lift for easy handling on site.

High External Static Pressure on Condensers
With a newly designed fan, fan guard, motor, and casing, new models can be custom-installed on-site to provide up to 80 Pa of external static pressure. An air discharge duct prevents shortages of air circulation, allowing outdoor units to be installed on every floor of a building.

Low-Noise Operation
Numerous technological innovations, including an improved compressor and a newly designed bell mouth and larger fan, have dramatically reduced the outdoor noise level. The result is an even more comfortable building environment.

Why Panasonic
Talk to our Air Design Specialists