$ #,###.00 000 false categorybrowsepage,comparepage,wishlistpage,learncontentpage false productpage false 010 //panasonic-australia.ibrandiq.com/en/Widgets/FluidPanAU/{0} //panasonic-australia.ibrandiq.com/Products/MultipleInStock/FluidPanAU/{0}
Photo of 8.0kW ECONAVI Reverse Cycle Inverter Air Conditioner

8.0kW ECONAVI Reverse Cycle Inverter Air Conditioner

General Indoor Unit CS-E28PKR
Outdoor Unit CU-E28PKR
Function Cooling + Heating
PERFORMANCE Cooling Capacity Rated Conditions (kW) 8
Cooling Capacity Range - Min ~ Max (kW) 2.30 ~ 8.60
EER (w/w) 3.35
Heating Capacity Rated Conditions (kW) 9
Heating Capacity Range - Min ~ Max (kW) 2.20 ~ 11.00
COP (w/w) 3.42
Star Rating - Cool / Heat 2.0 / 2.0
SPECIFICATIONS Electrical Voltage (V) 240
Running Current - Cool / Heat (A) 10.9 / 11.9
Power Input - Cool / Heat (kW) 2.39 / 2.63
Sound Pressure Indoor - Cool - Hi / Lo / S-Lo (dB(A)) 51 / 38 / 35
Sound Pressure Indoor - Heat - Hi / Lo / S-Lo (dB(A)) 50 / 38 / 35
Sound Pressure Outdoor - Cool - Hi / S-Lo (dB(A)) 55 / 50
Sound Pressure Outdoor - Heat - Hi / S-Lo (dB(A)) 55 / 50
Sound Power Outdoor - Cool - Hi / S-Lo (dB) 73 / 68
Sound Power Outdoor - Heat - Hi / S-Lo (dB) 73 / 68
Quiet Mode - Indoor (dB) 35
Quiet Mode - Outdoor (dB) 50
Dehumidify (L/h) 4.7
Air Flow - Cool / Heat (L/s) 359 / 357
Indoor Dimensions - H x W x D (mm) 290 x 1070 x 240
Outdoor Dimensions - H x W x D (mm) 1170 x 900 x 320
Weight - Indoor (kg) 12
Weight - Outdoor (kg) 74
Refrigerant Pipe Diameter - Liquid Side / Gas Side (mm) 6.35 / 15.88
Piping Extension Length Min ~ Max (m) 3 ~ 30
Pipe Length for Additional Gas (m) 10
Additional Refrigerant (R410A) (g/m) 30
Power Supply Outdoor
Operating Temperature Range - Outdoor - Cooling (˚C) 5 ~ 46
Operating Temperature Range - Outdoor - Heating (˚C) -15 ~ 24
Warranty - Residential 5 Years Manufacturer's Warranty
FEATURES - Healthier Air Nonoe-g Air Purifying System Yes
Anti Bacterial Air Filter -
Odour Removing Function Yes
Removable, Washable Panel Yes
FEATURES - Comfort ECONAVI Yes
AUTOCOMFORT Yes
Inverter Control Yes
Mild Dry Cooling Yes
Powerful Mode Yes
Economy Mode -
Heating Operation Lower Limit (o C) -15
Cooling Operation Higher Limit (o C) 46
Soft Dry Operation Mode Yes
Fan Mode Yes
Remote Airflow Control (All directions) Yes
Remote Airflow control (Up & Down) -
Manual Horizontal Airflow Direction Control -
Auto Changeover - Inverter Yes
Automatic Operation Mode -
Hot Start Control Yes
FEATURES - Convenience 24-hour Dual On / Off Real Setting Timer Yes
12-hour On / Off Timer -
Demand Response Compatible Yes
3rd Party Connectivity Yes
LCD Wireless Remote Controller Large
Wired Remote Controller Optional
FEATURES - Reliability Blue Fin Condenser Yes
Random Auto Restart Yes
Long Piping (m) 30
Top-panel Maintenance Access Yes
Self Diagnostic Function Yes