CS-EU24BKXF, nanoe X™ Technology Air Conditioner

Photo of CS-EU24BKXF, nanoe X™ Technology Air Conditioner

Tonnage Class

  • TR

    • 2.0

Model

  • CS/CU-EU24BKXF-8

T1

  • Cooling Capacity

    • BTU/hr

      • 24000
  • Power

    • W

      • 1970
  • EER

    • BTU/hr/W

      • 12.183
  • Rated Current@230V

    • A

      • 9.0
  • Rated Current@240V

    • A

      • 8.6

T3

  • Cooling Capacity

    • BTU/hr

      • 21500
  • Power

    • W

      • 2400
  • EER

    • BTU/hr/W

      • 8.958
  • Rated Current@230V

    • A

      • 11.0
  • Rated Current@240V

    • A

      • 10.5

Max. Input Power

  • W

    • 2660

Max. Input Current

  • A

    • 12.2

Power supply source

  • V/Ph/Hz

    • 220~240/1/50

Air Flow Volume

  • m³/h

    • 1224

Noise level

  • Indoor (H/Q)

    • dB(A)

      • 49/36
  • Outdoor

    • dB(A)

      • 57

Net Weight (IDU [ODU]) (Kg)

  • 12.5 [29.6]

Gross Weight (IDU [ODU]) (Kg)

  • 14.5 [32.6]

Net Dimensions of the Indoor Unit

  • Length(L)

    • cm

      • 104.0
  • Breadth(B)

    • cm

      • 24.4
  • Height (H)

    • cm

      • 29.6

Gross Dimensions of the Indoor Unit

  • Length(L)

    • cm

      • 114.8
  • Breadth(B)

    • cm

      • 31.4
  • Height (H)

    • cm

      • 38.3

Net Dimensions of the Outdoor Unit

  • Length(L)

    • cm

      • 82.4
  • Breadth(B)

    • cm

      • 29.9
  • Height (H)

    • cm

      • 61.9

Gross Dimensions of the Outdoor Unit

  • Length(L)

    • cm

      • 97.0
  • Breadth(B)

    • cm

      • 41.6
  • Height (H)

    • cm

      • 70.0

Refrigerant

  • R-32

Operating Temp. Range

  • °C

    • 16 ~ 55

Operating Volt. Range

  • V

    • 198 ~ 264V

Refrigerant Pipe Diameter

  • Liquid Valve

    • cm

      • Ø0.635
  • Gas Valve

    • cm

      • Ø1.588

Chargeless Pipe Length

  • mm

    • 7.5

Max. Pipe Length

  • 20

Max. Height Difference

  • 10

Container Loading

  • sets

    • 155