H1 Type High Fresh Air Ducted

H1 Type High Fresh Air Ducted

High static and large airflow ducted with fresh air intake

H1 Type High Static Ducted units offer improved design flexibility in extended duct layouts thanks to their increased external static pressure. They also provide 100% fresh air intake for ventilation.
  • R410A
  • High Fresh Air
Zoom In
Zoom Out
Close

Specifications

S-140MH1H5

Photo of S-140MH1H5

S-224MH1H5

Photo of S-224MH1H5

S-280MH1H5

Photo of S-280MH1H5
  • R410AR410A
  • High Fresh AirHigh Fresh Air

100% fresh air intake for ventilation purpose

Design flexibility with high static pressure and large air volume

Discharge air temperature control to reduce cold drafts during heating operation

Configurable air temperature control

S-140MH1H5 S-224MH1H5 S-280MH1H5
Power Source 220/230/240 V, 1 phase - 50 Hz 220/230/240 V, 1 phase - 50 Hz 220/230/240 V, 1 phase - 50 Hz
Cooling Capacity 14.0 kW, 47,800 Btu/h 22.4 kW, 76,400 Btu/h 28.0 kW, 95,500 Btu/h
Heating Capacity 13.2 kW, 45,000 Btu/h 21.2 kW, 72,300 Btu/h 26.5 kW, 90,400 Btu/h
Power Input (Cooling) 0.430/0.430/0.430 kW 0.670/0.670/0.670 kW 0.730/0.730/0.730 kW
Power Input (Heating) 0.430/0.430/0.430 kW 0.670/0.670/0.670 kW 0.730/0.730/0.730 kW
Running Current (Cooling) 2.0/1.9/1.9 A 3.2/3.1/3.0 A 3.6/3.4/3.3 A
Running Current (Heating) 2.0/1.9/1.9 A 3.2/3.1/3.0 A 3.6/3.4/3.3 A
Fan Type Sirocco Fan Sirocco Fan Sirocco Fan
Air Flow Rate (H/M/L) 1,560 m³/h, 433 L/s 1,800 m³/h, 500 L/s 2,100 m³/h, 583 L/s
Fan Motor Output 0.3 kW 0.38 kW 0.38 kW
Sound Power Level (H/M/L) 75/76/76 dB 78/79/79 dB 79/80/80 dB
Sound Pressure Level (H/M/L) 43/44/44 dB (A) 46/47/47 dB (A) 47/48/48 dB (A)
Dimension H420 x W1,065 x D620 mm H479 x W1,428 x D1,230 mm H479 x W1,428 x D1,230 mm
Pipe Connection (Liquid) Ø9.52 mm (Ø3/8 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch)
Pipe Connection (Gas) Ø15.88 mm (Ø5/8 inch) Ø25.4 mm (Ø1 inch) Ø25.4 mm (Ø1 inch)
Pipe Connection (Drain Piping) VP-25 VP-25 VP-25
Net Weight 50 kg 110 kg 110 kg

Documents

Combination

Case Studies

Features

Cooling/Heating kW (rated)

14.0/13.2

22.4/21.2

28.0/26.5

Cooling/Heating Btu/h (rated)

47,800/45,000

76,400/72,300

95,500/90,400

Model No.

S-140MH1H5

S-224MH1H5

S-280MH1H5

Fresh Air Intake Possible

High Fresh System enables the delivery of fresh outside air at almost the same temperature and humidity as indoor air without putting a burden on air conditioning.
Note: Capable of treating outdoor air only. Indoor air conditioner units are required to adjust indoor air temperature.
Fresh Air Intake Possible

Mix Operation Unit with Standard Indoor Units

Possible to combine high fresh air ducted indoor units and standard air ducted indoor units. When other indoor units are connected in the same circuit, keep the following capacity ratio. H1 type / outdoor unit < 30%, and total of indoors (incl. H1) / outdoor < 100%
Mix Operation Unit with Standard Indoor Units

3-Step Static Pressure Set Up

An inspection port (600 x 600 mm or more) is required at the lower side of the indoor unit body (field supply).
3-Step Static Pressure Set Up

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Optional Parts for High Static Ducted Series

Model Indoor Unit

Model Outdoor Unit

Operation

RAP Valve Kit

3-Way Control PCB

3-Way Valve Kit
(Single SVK)

3-Way Valve Kit
Multiple Connection Port Type 4 Ports
(Multiple SVK)

Distribution Joint Kit
(2-Way)

Distribution Joint Kit
(3-Way)

CZ-P160RVK2

CZ-CAPE2

CZ-P160HR3

CZ-P4160HR3
(160 Type x 4)

Solenoid Valve Relay Kit
(Accessary Parts)

CZ-P160BK2
for 22.4 kW or less

CZ-P680BK2
for more than 22.4 kW

CZ-P224BH2
for 22.4 kW or less

CZ-P680BH2
for more than 22.4 kW

H1 Type
High Fresh Air Ducted
・ S-224MH1H5
・ S-280MH1H5

2-Way ME1, ME2, MS3

Cooling Only

-

-

-

-

-

-

-

2-Way ME1&ME2

Cooling or Heating

2 pcs

-

-

-

-

2 pcs

-

H1 Type
High Fresh Air Ducted
・ S-140MH1H5

2-Way ME1, ME2, MS3

Cooling Only

-

-

-

-

-

-

-

2-Way ME1&ME2

Cooling or Heating

1 pc

-

-

-

-

-

-

*Valve Kit is not required for cooling only system. For the details on the information, please consult an authorised dealer.