AK-HCU200 | |
---|---|
Power Supply: | 100 V to 240 V AC, 50/60 Hz |
Power Consumption: | 170 W (Without CAMERA connected: 32 W) |
Capacity for Supplying Power to a Camera: | 190 V DC, 0.6 A |
Operating Temperature: | 0 °C to 40 °C (32 °F to 104 °F) |
Operating Humidity: | 10 % to 90 % (no condensation) |
Dimensions (W x H x D): | 424 mm × 88 mm × 400 mm (16-11/16 inches × 3-7/16 inches × 15-3/4 inches) Excluding protrusions |
Weight: | Approx. 6.6 kg (approx. 14.6 lb) |
Video Output: | HD SDI/SD SDI: 4 lines (2 lines shared with picture monitor output*2) Analog composite: 1 line (1 line shared with picture monitor output*2) |
Return Input: | HD SDI/SD SDI: 2 lines (switched depending on the setting) VBS: 1 line |
Prompter Input: | 1 line, Analog composite |
Reference Input: | 1 line (1 loop-through line) Black burst/tri-level*3 |
Microphone Output: | 2 lines (XLR, 3-pin, male), 0 dBm/600 Ω |
Intercom: | XLR, 5-pin, female Input: –55 dBu to –10 dBu Output: 100 mW (max.) |
COMMUNICATION: | Intercom input/output: 2 lines (1/2*2) (0 dBm, 600 Ω, RTS/4W*2) PGM: 1 line, input (0 dBm/600 Ω) Tally input: Red, Green, 1 input each |
ROP interface: | RS-422, 1 line, 12 V output |
MSU interface: | RS-422, 1 line, GPI for control |
LAN port: | 1 line (10Base-T/100Base-TX, RJ45, crossover cable, category 5 or above) For computer connection |
*2: Depending on the setting, only one of them can be selected at one time. | |
*3: The black burst signal and tri-level sync signal of the reference input are recognized automatically. |