Retail Sales Price: Panasonic Online Price: SHOP NOW Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

T2 Type Ceiling Mounted

Add to WishlistRemove from Wishlist

NO ROOM TO ADD MORE PRODUCTS

The wishlist has already reached the maximum number of products

T2 Type Ceiling Mounted

Outstanding energy-saving performance and airflow, and compact design

T2 Type Ceiling Mounted units offer excellent energy-saving performance and comfortable long-distance airflow distribution, making them ideal for stores and schools.
  • ECONAVI
  • R410A
Zoom In
Zoom Out
Close

Specs

S-36MT2E5A

Photo of S-36MT2E5A

S-45MT2E5A

Photo of S-45MT2E5A

S-56MT2E5A

Photo of S-56MT2E5A

S-73MT2E5A

Photo of S-73MT2E5A

S-106MT2E5A

Photo of S-106MT2E5A

S-140MT2E5A

Photo of S-140MT2E5A
  • ECONAVIECONAVI
  • R410AR410A
  • DC motorDC motor

Lower sound levels

Long and wide air distribution

Fresh air knockout

Standardised height and depth for all models

Easy to install and maintain

S-36MT2E5A S-45MT2E5A S-56MT2E5A S-73MT2E5A S-106MT2E5A S-140MT2E5A
Power Source 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz
Cooling Capacity 3.6 kW, 12,300 Btu/h 4.5 kW, 15,400 Btu/h 5.6 kW, 19,100 Btu/h 7.3 kW, 24,900 Btu/h 10.6 kW, 36.200 Btu/h 14.0 kW, 47,800 Btu/h
Heating Capacity 4.2 kW, 14,300 Btu/h 5.0 kW, 17,100 Btu/h 6.3 kW, 21,500 Btu/h 8.0 kW, 27,300 Btu/h 11.4 kW, 38,900 Btu/h 16.0 kW, 54,600 Btu/h
Power Input (Cooling) 0.035/0.035/0.035 kW 0.040/0.040/0.040 kW 0.040/0.040/0.040 kW 0.055/0.055/0.055 kW 0.080/0.080/0.080 kW 0.100/0.100/0.100 kW
Power Input (Heating) 0.035/0.035/0.035 kW 0.040/0.040/0.040 kW 0.040/0.040/0.040 kW 0.055/0.055/0.055 kW 0.080/0.080/0.080 kW 0.100/0.100/0.100 kW
Running Current (Cooling) 0.37/0.36/0.35 A 0.39/0.38/0.37 A 0.39/0.38/0.37 A 0.45/0.44/0.43 A 0.69/0.67/0.65 A 0.82/0.79/0.77 A
Running Current (Heating) 0.37/0.36/0.35 A 0.39/0.38/0.37 A 0.39/0.38/0.37 A 0.45/0.44/0.43 A 0.69/0.67/0.65 A 0.82/0.79/0.77 A
Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Air Flow Rate (H/M/L) 840/720/630 m³/h, 233/200/175 L/s 900/750/630 m³/h, 250/208/175 L/s 900/750/630 m³/h, 250/208/175 L/s 1,260/1,080/930 m³/h, 350/300/258 L/s 1,800/1,500/1,380 m³/h, 500/417/383 L/s 1,920/1,680/1,440 m³/h, 533/467/400 L/s
Fan Motor Output 0.043 kW 0.043 kW 0.043 kW 0.074 kW 0.111 kW 0.111 kW
Sound Power Level (H/M/L) 54/50/48 dB 55/51/48 dB 55/51/48 dB 57/53/51 dB 60/55/54 dB 62/58/55 dB
Sound Pressure Level (H/M/L) 36/32/30 dB (A) 37/33/30 dB (A) 37/33/30 dB (A) 39/35/33 dB (A) 42/37/36 dB (A) 44/40/37 dB (A)
Dimension H235 x W960 x D690 mm H235 x W960 x D690 mm H235 x W960 x D690 mm H235 x W1,275 x D690 mm H235 x W1,590 x D690 mm H235 x W1,590 x D690 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch)
Pipe Connection (Drain Piping) VP-20 VP-20 VP-20 VP-20 VP-20 VP-20
Net Weight 27 kg 27 kg 27 kg 33 kg 40 kg 40 kg

Documents

Combination

Case Studies

Features

Cooling/Heating kW (rated)

3.6/4.2

4.5/5.0

5.6/6.3

7.3/8.0

10.6/11.4

14.0/16.0

Cooling/Heating Btu/h (rated)

12,300/14,300

15,400/17,100

19,100/21,500

24,900/27,300

36,200/38,900

47,800/54,600

Model No.

S-36MT2E5A

S-45MT2E5A

S-56MT2E5A

S-73MT2E5A

S-106MT2E5A

S-140MT2E5A

Airflow Creates a Comfortable and Cool Environment

Cools the Area Quickly

Optimization of the shape of the casing and fan ensures bigger airflow. Powerful airflow delivered instantly makes all areas of spaces comfortable and cool.
Note: This table shows values for the airflow rate in high mode.
Cools the Area Quickly

Delivers Cool Air Over a Long Distance

The shape of the outlet has been optimized to provide long-distance airflow distribution. Cool air can reach up to 13 meters* away, so even deep and wide spaces are comfortable.
*Results are based on specific testing conditions.
Delivers Cool Air Over a Long Distance

Cools Spaces in Their Entirety

In addition to the wide air discharge opening, the louvers can be adjusted manually up to 90 degrees left and right, and automatically up to 30 degrees up and down. You can choose to distribute cool air to every part of a large space or deliver cool air to only places where you want it to go. You can use the unit in any way you like.
Cools Spaces in Their Entirety

Compact Looking, Stylish, Streamlined Design

With its streamlined form, the unit looks slim and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while keeping the unit clean.
Compact Looking, Stylish, Streamlined Design

ECONAVI Sensor

Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.

1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximise the energy-saving effect.
ECONAVI Sensor

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Flexible Installation

With its streamlined form, the unit looks slim and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while keeping the unit clean.
Compact Looking, Stylish, Streamlined Design

The 5-directional drain pipe and 3-directional refrigerant pipe make installation much easier. And the neat fit with walls and ceilings assures more installation flexibility.
Multiple Piping Directions for Flexible Installation