Retail Sales Price: Panasonic Store Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Store In stock /content/dam/Panasonic/EC-icon/icn-stock-in.png In stock Out of stock /content/dam/Panasonic/EC-icon/icn-stock-out.png Out of stock Pre-order /content/dam/Panasonic/EC-icon/icn-stock-soon.png Pre-order Panasonic false false You need to accept cookie policy if you want to add to cart. You need to opt in cookie policy if you want to add to cart. VISIT Panasonic ONLINE SHOP Photo of {0} false false false

K2 Type Wall Mounted

SHOP NOW

K2 Type Wall Mounted

Its compact size and stylish smooth design make it ideal for small offices

K2 Type Wall Mounted units boast a stylish design and are compact and lightweight, making them easy to install. Their quiet operation makes them ideal for small offices, hotel rooms, and hospital rooms.
  • ECONAVI
  • R410A
Zoom In
Zoom Out
Close

Features

Cooling/Heating kW (rated)

2.2/2.5

2.8/3.2

3.6/4.2

4.5/5.0

5.6/6.3

7.3/8.0

10.6/11.4

Cooling/Heating Btu/h (rated)

7,500/8,500

9,600/10,900

12,300/14,300

15,400/17,100

19,100/21,500

24,900/27,300

36,200/38,900

Model No.

S-22MK2E5A

S-28MK2E5A

S-36MK2E5A

S-45MK2E5A

S-56MK2E5A

S-73MK2E5A

S-106MK2E5A

Cools the Area Quickly

Powerful airflow instantly makes spaces comfortable and cool.
Note: This table shows values for the airflow rate in high mode.
Cools the Area Quickly

Auto Air Distribution

The air outlet angle is automatically adjusted for cooling and heating operations.
Auto Air Distribution

ECONAVI Sensor

Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.

1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximise the energy-saving effect.
ECONAVI Sensor

Washable Front Panel

The indoor unit’s front panel can be easily removed and washed for trouble-free maintenance.
Washable Front Panel

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Flexible Installation

With a compact indoor unit, a piping outlet is possible in the six directions of right, right rear, right bottom, left, left rear, and left bottom, making installation easier.
Flexible Installation Options

The Noise Reducing External Valve kit reduces the noise level of the expansion valve. (Optional accessory)

・ CZ-P56SVK2 for 22-56 type
・ CZ-P160SVK2 for 73*-106 type
*When the pipe diameter is (Liquid) Ø6.35- (Gas) Ø12.7, please use CZ-P56SVK2.
Noise Reducing External Valve Kit

Specs

S-22MK2E5A

Photo of S-22MK2E5A

S-28MK2E5A

Photo of S-28MK2E5A

S-36MK2E5A

Photo of S-36MK2E5A

S-45MK2E5A

Photo of S-45MK2E5A

S-56MK2E5A

Photo of S-56MK2E5A

S-73MK2E5A

Photo of S-73MK2E5A

S-106MK2E5A

Photo of S-106MK2E5A
  • ECONAVIECONAVI
  • R410AR410A
  • DC motorDC motor

Closed discharge port when not in use

Lighter and smaller units make installation easy

Quiet operation

Smooth and durable design and washable front panel

Piping outlet in six directions

Air distribution is automatically altered depending on the operational mode of the unit

S-22MK2E5A S-28MK2E5A S-36MK2E5A S-45MK2E5A S-56MK2E5A S-73MK2E5A S-106MK2E5A
Power Source 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz
Cooling Capacity 2.2 kW, 7,500 Btu/h 2.8 kW, 9,600 Btu/h 3.6 kW, 12,300 Btu/h 4.5 kW, 15,400 Btu/h 5.6 kW, 19,100 Btu/h 7.3 kW, 24,900 Btu/h 10.6 kW, 36,200 Btu/h
Heating Capacity 2.5 kW, 8,500 Btu/h 3.2 kW, 10,900 Btu/h 4.2 kW, 14,300 Btu/h 5.0 kW, 17,100 Btu/h 6.3 kW, 21,500 Btu/h 8.0 kW, 27,300 Btu/h 11.4 kW, 38,900 Btu/h
Power Input (Cooling) 0.025/0.025/0.025 kW 0.025/0.025/0.025 kW 0.030/0.030/0.030 kW 0.030/0.030/0.030 kW 0.035/0.0.35/0.035 kW 0.055/0.055/0.055 kW 0.080/0.080/0.080 kW
Power Input (Heating) 0.025/0.025/0.025 kW 0.025/0.025/0.025 kW 0.030/0.030/0.030 kW 0.030/0.030/0.030 kW 0.035/0.0.35/0.035 kW 0.055/0.055/0.055 kW 0.080/0.080/0.080 kW
Running Current (Cooling) 0.21 A 0.23 A 0.25 A 0.33/0.32/0.31 A 0.36/0.35/0.34 A 0.52/0.51/0.50 A 0.72/0.70/0.68 A
Running Current (Heating) 0.21 A 0.23 A 0.25 A 0.33/0.32/0.31 A 0.36/0.35/0.34 A 0.52/0.51/0.50 A 0.72/0.70/0.68 A
Fan Type Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan Cross-Flow Fan
Air Flow Rate (H/M/L) 540/450/390 m³/h, 150/125/108 L/s 570/498/390 m³/h, 158/138/108 L/s 654/540/390 m³/h, 182/150/108 L/s 870/750/600 m³/h, 242/208/167 L/s 960/840/720 m³/h, 267/233/200 L/s 1,170/1,020/840 m³/h, 325/283/233 L/s 1,290/1,110/900 m³/h, 358/308/250 L/s
Fan Motor Output 0.03 kW 0.03 kW 0.03 kW 0.054 kW 0.054 kW 0.054 kW 0.054 kW
Sound Power Level (H/M/L) 51/48/44 dB 52/49/44 dB 55/51/44 dB 53/50/48 dB 55/52/50 dB 62/59/55 dB 64/61/57 dB
Sound Pressure Level (H/M/L) 36/33/29 dB (A) 37/34/29 dB (A) 40/36/29 dB (A) 38/35/33 dB (A) 40/37/35 dB (A) 47/44/40 dB (A) 49/46/42 dB (A)
Dimension H290 x W870 x D214 mm H290 x W870 x D214 mm H290 x W870 x D214 mm H302 x W1,120 x D236 mm H302 x W1,120 x D236 mm H302 x W1,120 x D236 mm H302 x W1,120 x D236 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø9.52 mm (Ø3/8 inch) Ø9.52 mm (Ø3/8 inch)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø15.88 mm (Ø5/8 inch) Ø15.88 mm (Ø5/8 inch)
Pipe Connection (Drain Piping) Ø18 mm Ø18 mm Ø18 mm Ø18 mm Ø18 mm Ø18 mm Ø18 mm
Net Weight 9 kg 9 kg 9 kg 13 kg 13 kg 14 kg 14 kg

Documents

Combination

Case Studies