Y3 Type 4-Way Mini Cassette

SHOP NOW

Y3 Type 4-Way Mini Cassette (Mark3)

Compact design, easy installation, and excellent air purification functionality

Y3 Type 4-Way Mini Cassette units feature a design compact enough to fit into a 60 × 60 cm ceiling grid with easy installation. They also offer the next level of air quality thanks to the nanoe X Generator Mark3.
  • nanoe X Generator Mark3
  • R410A
Zoom In
Zoom Out
Close
Y3 Type 4-Way Mini Cassette (Mark3)

Features

Cooling/Heating kW (rated)

2.2/2.5

2.8/3.2

3.6/4.2

4.5/5.0

5.6/6.3

Cooling/Heating Btu/h (rated)

7,500/8,500

9,600/10,900

12,300/14,300

15,400/17,100

19,100/21,500

Model No.

S-22MY3E

S-28MY3E

S-36MY3E

S-45MY3E

S-56MY3E

A New Level of Air Quality with nanoe X Generator Mark3

24-hour nanoe™ X Air Protection

nanoe™ X inhibits certain bacteria, viruses, pollens, allergens, mould, and hazardous substances contained in PM2.5. Providing effective deodorisation and improving the quality of your air. nanoe™ X functions in both cooling and fan modes, and is maintenance-free, helping you enjoy 24 hours of quality air while keeping your costs down.
24-hour nanoe™ X Air Protection

Higher Concentration, Even in Large Space

The amount of hydroxyl radicals generated increased 100 times, compared to the original nanoe™, which achieves greater effectiveness even in large spaces of 112 m².
Conditions of the simulation ・Room size: 112 m² ・Room height: 2.4 m ・Inspection model: 4-Way Cassette ・Position of IDU: Centre
Note: The result is based on the conditions for the simulation and it may differ from the concentration measured in an actual room. nanoe™ particles are extremely tiny in nano-meter size. They cannot be seen, so the concentration image is solely for illustrative purposes.
Higher Concentration, Even in Large Space

Effective at Eliminating Odours in Only 30 Minutes

The nanoe X Generator Mark3 reduces odours by as much as 1.8 levels* in just 30 minutes. This is half the time required to achieve the same effect compared to the conventional nanoe X Generator Mark 2.
*A 1.8 level decrease in odour intensity is equivalent to a reduction of 95% or more.
[Odour intensity] 5: Very strong odour, 4: Strong odour, 3: Easily detectable odour, 2: Weak, recognisable odour (cognitive threshold concentration), 1: Barely detectable odour (detection threshold concentration), 0: No odour

Note: The test result is obtained using a 4-Way Cassette. **Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P80U6 equipped with a nanoe X Generator Mark2 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 60 minutes (L19YK032-01) ***Testing Overview: [Testing organisation] Panasonic Product Analysis Center [Test method] Verification in a test room (approx. 230 m³ (6.8 x 8.5 x 4.0 m)) using a 6-step odour intensity display method [Method of deodorisation] Operation of a CS-P160U6 equivalent tester equipped with a nanoe X Generator Mark3 and release of nanoe™ [Target] Adhered aging odour (nonenal) [Test Result] Odour intensity reduced by 1.8 in 30 minutes (R21HM003-0)
Effective at Eliminating Odours in Only 30 Minutes

Inside Cleaning Function to Suppress Mould Growth

After cooling/drying operation, the inside of the indoor unit is automatically dried.* nanoe™ X is activated to suppress mould growth.
*If you wish to set the inside cleaning function off, use the wireless remote controller to turn the function off. Please consult an authorized dealer for setting.
Note: The product image shown is for illustration purposes only and may not be an exact representation of the product.
Inside Cleaning Function to Suppress Mould Growth

Pleasant Airflow

Cools All Areas Quickly

Powerful airflow delivered from all four sides of the unit instantly transforms all areas of spaces into a comfortable and cool environment.
Note: This table shows values for the airflow rate in high mode.
Cools All Areas Quickly

Individual Flap Control Allows You to Cool the Environment as You Like

Better control of the airflow with four motors, providing individual flap control. 4-way and auto swing louvers offer uniform airflow to all corners of the room. The louvers can be angled individually to deliver the optimal amount of cool air to all areas. You can cool spaces in a way that suits you.
Individual Flap Control Allows You to Cool the Environment as You Like

Flat Horizontal Design That Conditions the Interior

Panasonic believes that one of the most important elements of design is that it doesn’t interfere with the overall room interior. The flat horizontal design of the 4-Way Mini Cassette achieves an elegant yet simple form. This design allows it to protrude only 30 mm from the ceiling, to blend naturally into a variety of interiors, including offices and restaurants.
Flat Horizontal Design That Conditions the Interior

ECONAVI Sensor

Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.

1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximise the energy-saving effect.
ECONAVI Sensor

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Flexible Installation

Thanks to advanced Panasonic design, the panel is a compact 625 x 625 mm, offering elegant, unobtrusive installation even where space is limited.
Compact Design

With a low body height of 230 mm, it can easily fit in limited spaces and tight spots. (Required 243 mm from bottom of the panel to top of the unit)
Lighter and Slimmer, Easier Installation

The internal pump allows the drain pipe to be elevated up to 850 mm from the lower surface of the body. Long horizontal piping is also possible.
A Drain Height of Up to 850 mm from the Ceiling Surface

Specs

S-22MY3E

Photo of S-22MY3E

S-28MY3E

Photo of S-28MY3E

S-36MY3E

Photo of S-36MY3E

S-45MY3E

Photo of S-45MY3E

S-56MY3E

Photo of S-56MY3E
  • nanoe X Generator Mark3nanoe X Generator Mark3
  • R410AR410A
  • DC motorDC motor
  • Drain PumpDrain Pump

4-Way Mini Cassette fits into a 60 x 60 cm ceiling grid

Powerful drain pump gives 850 mm lift

DC fan motor with variable speed and a new heat exchanger ensures efficient power consumption

Multi-directional airflow

nanoe™ X: 100 times more nanoe™ particle for wide commercial space

S-22MY3E S-28MY3E S-36MY3E S-45MY3E S-56MY3E
Power Source 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz
Cooling Capacity 2.2 kW, 7,500 Btu/h 2.8 kW, 9,600 Btu/h 3.6 kW, 12,300 Btu/h 4.5 kW, 15,400 Btu/h 5.6 kW, 19,100 Btu/h
Heating Capacity 2.5 kW, 8,500 Btu/h 3.2 kW, 10,900 Btu/h 4.2 kW, 14,300 Btu/h 5.0 kW, 17,100 Btu/h 6.3 kW, 21,500 Btu/h
Power Input (Cooling) 0.020 kW 0.021 kW 0.022 kW 0.030 kW 0.042 kW
Power Input (Heating) 0.018 kW 0.019 kW 0.020 kW 0.028 kW 0.040 kW
Running Current (Cooling) 0.25/0.24/0.23 A 0.26/0.25/0.24 A 0.27/0.26/0.25 A 0.35/0.34/0.33 A 0.44/0.43/0.42 A
Running Current (Heating) 0.22/0.21/0.20 A 0.23/0.22/0.21 A 0.24/0.23/0.22 A 0.32/0.31/0.30 A 0.41/0.40/0.39 A
Fan Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Air Flow Rate (H/M/L) 522/420/360 m³/h, 145/117/100 L/s 540/450/360 m³/h, 150/125/100 L/s 570/468/360 m³/h, 158/130/100 L/s 690/540/390 m³/h, 192/150/108 L/s 810/630/480 m³/h, 225/175/133 L/s
Fan Motor Output 0.03 kW 0.03 kW 0.03 kW 0.03 kW 0.03 kW
Sound Power Level (Cooling) (H/M/L) 48/45/43 dB 49/45/43 dB 50/46/43 dB 54/49/45 dB 57/52/48 dB
Sound Power Level (Heating) (H/M/L) 48/45/43 dB 49/45/43 dB 50/46/43 dB 54/49/45 dB 57/52/48 dB
Sound Pressure Level (Cooling) (H/M/L) 33/30/28 dB (A) 34/30/28 dB (A) 35/31/28 dB (A) 39/34/30 dB (A) 42/37/33 dB (A)
Sound Pressure Level (Heating) (H/M/L) 33/30/28 dB (A) 34/30/28 dB (A) 35/31/28 dB (A) 39/34/30 dB (A) 42/37/33 dB (A)
Dimension H243 x W575 x D575 mm H243 x W575 x D575 mm H243 x W575 x D575 mm H243 x W575 x D575 mm H243 x W575 x D575 mm
Dimension with the Optional Ceiling Panel H273 x W625 x D625 mm H273 x W625 x D625 mm H273 x W625 x D625 mm H273 x W625 x D625 mm H273 x W625 x D625 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch) Ø6.35 mm (Ø1/4 inch)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch) Ø12.7 mm (Ø1/2 inch)
Pipe Connection (Drain Piping) VP-20 VP-20 VP-20 VP-20 VP-20
Net Weight 15 kg 15 kg 15 kg 15 kg 15 kg
Net Weight with the Optional Ceiling Panel 17.8 kg 17.8 kg 17.8 kg 17.8 kg 17.8 kg