HE-UM60AR
Heat output at 19.0°C ambient / 14.0°C cold water inlet*
-
5.0kW
Electric input at 19.0°C ambient / 14.0°C cold water inlet*
-
0.96kW
COP at 19.0°C ambient / 14.0°C cold water inlet*
-
5.2
Power input (Max)
-
2.3kW
Current input (Max)
-
10A
Circuit breaker size
-
15A
Standby power consumption
-
5.05W
Power supply
-
230V/Hz - 240V/Hz Vac (power input is voltage x amps x power factor) / 50Hz (single phase)
Heat pump refrigerant
-
CO₂ (R744)
Heat pump hot water delivery temperature
-
63°C - 67°C Variable (based on heat pump inlet temperature
Range of operating ambient temperature
-
-10°C to 43°C
Heat pump unit weight
-
46kg
Heat pump location
-
Outdoor
Noise level
-
37dB
Dimensions (H x W x D)
-
672mm x 799mm x 299mm
Rain resistance
-
IPX4
Water port connections (Inlet / Outlet)
-
1/2" BSP, 12.7mm
Built-in freeze and frost control
-
Variable. Depends on the relative humidity, water, & ambient temperature (i.e. about 5°C water temperature & 5°C ambient temperature).
Note
-
*As per AS/NZ Standard 5125