F2 Type: Mid Static Ducted
Designed specifically for applications requiring fixed square ducting.

Cooling/Heating kW (rated) |
2.2/2.5 |
2.8/3.2 |
3.6/4.2 |
4.5/5.0 |
5.6/6.3 |
6.0/7.1 |
---|---|---|---|---|---|---|
Cooling/Heating Btu/h (rated) |
7,500/ |
9,600/ |
12,300/ |
15,400/ |
19,100/ |
20,500/ |
Model No. |
S-22MF2E5A |
S-28MF2E5A |
S-36MF2E5A |
S-45MF2E5A |
S-56MF2E5A |
S-60MF2E5A |
Cooling/Heating kW (rated) |
7.3/8.0 |
9.0/10.0 |
10.6/11.4 |
14.0/16.0 |
16.0/18.0 |
---|---|---|---|---|---|
Cooling/Heating Btu/h (rated) |
24,900/ |
30,700/ |
36,200/ |
47,800/ |
54,600/ |
Model No. |
S-73MF2E5A |
S-90MF2E5A |
S-106MF2E5A |
S-140MF2E5A |
S-160MF2E5A |
Document
Features
Slim & Compact Design
The Panasonic Slim-line ducted unit sits at only 290mm high. This market leading height enables easy installation into compact ceiling spaces.

Variable External Static Pressure Control
Optimal airflow set-up is possible depending on ducting design and conditions.
*Please refer to technical databook for detail.

System Example
An inspection port (450 mm x 450 mm or larger) is required at the lower side of the indoor unit body.

More Powerful Drain Pump
Using a high-lift drain pump, drain piping can be elevated up to 702 mm from the base of the unit.

Discharge Air Temperature Control
Smart sensors control discharge air temperature for precise room temperature control. Possible to reduce cold drafts during heating operation.

V-Shaped Heat Exchanger
To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency slit fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area by about 30 to 80%.

High Energy Efficiency
Through the use of state-of-the-art DC motors, Panasonic Slim Low Static Ducted units greatly reduce power consumption.

ECONAVI Sensor
Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.
1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximizethe energy saving effect

2-Way Mini-FSV LE Series
These compact, high-efficiency Mini FSV systems are specifically designed for the most demanding applications, with capacities from 12.1 kW to 28.0 kW.

2-Way FSV-EX ME2 Series
With extraordinary energy-saving performance and powerful operation, these heat pump systems feature a space-saving design, with capacities from 22.4 kW to 224 kW.

Leading Control Options
Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.

Why Panasonic
Talk to our Air Design Specialists