nanoe™ X

Concentration Simulation Results

Simulation Conditions

Type of indoor unit

Wall-mounted

Model type :

Residential

Room shape :

Square

Room size :

40 m²

Room height :

2.4 m

Position of indoor unit :

Center of the wall

Type of nanoe™ generator :

Mark 2

nanoe™ distribution and concentration level over time

There are 7 key benefits provided by nanoe™ which commence when concentration reaches Level 1.
The concentration level affects the speed at which the benefits occur.Concentration level 2 is 10 times the concentration of level 1, and concentration level 3 is 20 times the concentration of level 1.

*The results shown are for simulation purpose only and concentration may vary due to actual room conditions.

nanoe™ distribution and concentration level over time
Exaust Air (EA)

Exaust Air (EA)

Supply Air (SA)

Supply Air (SA)

1 minute later (nanoe™ concentration : approximately 30%)

1 minute later

Nivel de concentración de nanoe™

1 minute later

4 minute later (nanoe™ concentration : approximately 60%)

4 minute later

Nivel de concentración de nanoe™

4 minute later

9 minute later (nanoe™ concentration is almost stabilized)

9 minute later

Nivel de concentración de nanoe™

9 minute later

Room Conditions

• Room size : 6.32m x 6.32m x 2.4m (40㎡)
• Type of indoor unit : Wall-mounted
• Position of indoor unit or air outlet : As indicated in the image
• Ventilation
• Position of air inlet/outlet : As indicated in the image
• Amount of ventilation : 0.5 times/hour (amount of ventilation means number of times when air volume equivalent to the cubic capacity of the room is ventilated per hour)

Other Conditions

• Air volume : 15.7㎥/min (942㎥/hour) by 24,000BTU/h 7.1kW
• Air flow direction : To 45 degrees downward from the horizontal axis
• Amount of generated nanoe : 9.6 trillion/second
• Half-life of hydroxyl radical : Approximately 10 minutes
• Simulation method : Fluid/concentration diffusional analysis by finite volume method

Remarks

• The concentration level of nanoe™ is stabilized after a certain period of time time. This result shows the variability of nanoe™ diffusion at the 3 time
points until when nanoe™ concentration is stabilized.
• The diffusion of nanoe™ is not effected by the operation mode (heating, cooling, nanoe™ , etc.) of the air conditioner.
• Simulation was conducted as an independent space by dividing one home into individual room.
• nanoe™ particles are extremely tiny in nano-meter size. They cannot be seen so the concentration image is solely for illustrative purposes.

nanoe™ X

Concentration level of nanoe™ X is the key for effectiveness

7 Effects nanoe™ X

7 Effects nanoe™ X

Known as nature’s detergent, hydroxyl radicals (also known as OH radicals) are natural reactive molecules looking to react with other elements such as hydrogen. This reaction enables hydroxyl radicals to inhibit the growth of pollutants. Panasonic’s nanoe™ X technology brings these effects to purify surfaces and indoor environments.

The concentration level of nanoe™ X is the key to effectiveness. The higher the concentration, the more hydroxyl radicals are in the space, and the quicker the effect can be realised.

This will enable you to enjoy a pleasant and comfortable living space.

Level 1 : Effects expected at concentration Level 1

Adhered virus

Adhered virus

(1) Testing organisation: Japan Food Research Laboratories
(2) Test subject: Adhered bacteriophage Φ x 174
(3) Test volume: Approx. 25 m³ laboratory (3.3 x 3.5 x 2.2m)
(4) Test result: Inhibited 99.8% in 8 hours
(5) Report No.: 13001265005-01

Airborne virus

Airborne virus

(1) Testing organisation: Kitasato Research Center for Environmental Science
(2) Test subject: Airborne bacteriophage 174
(3) Test volume: Approx. 25 m³ laboratory (3.5 x 3.3 x 2.2m)
(4) Test result: Inhibited 99.74% in 6 hours
(5) Report No.: 24_0300_1

Bacteria

Bacteria

(1) Testing organisation: Japan Food Research Laboratories
(2) Test subject: Adhered staphylococcus aureus
(3) Test volume: Approx. 23 m³ laboratory (3.6 x 2.7 x 2.4m)
(4) Test result: Inhibited 99.1% in 8 hours
(5) Report No.: 13044083003-01

Mould

Mould

(1) Testing organisation: Japan Food Research Laboratories
(2) Test subject: Airborne cladsporium
(3) Test volume: Approx. 23 m³ laboratory (3.6 x 2.7 x 2.4m)
(4) Test result: Inhibited 99% in 1 hour
(5) Report No.: 205061541-001

Level 2 : Effects expected at concentration Level 2

Level 2 is 10 times more concentrated than Level 1, and compared to Level 1 takes less time to realise the effects.

Pollen

Pollen

After 8 hours
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test result: Inhibited over 88% in 8 hours
(5) Report No.: BAA33-130402-F0

After 24 hours
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 24 hours
(5) Report No.: 4AA33-151001-F01

Level 3 : Effects expected at concentration Level 3

Level 3 is 20 times more concentrated than Level 1, and compared to Level 2 takes less time to realise the effects.

Pollen
Time to inhibition of pollen up to 99%

Pollen

Level 2:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 24 hours
(5) Report No.: 4AA33-151001-F01

Level 3:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 12 hours confirmed
(5) Report No.: L19YA009

Age-related body odour
Time to reduce odour intensity by 1.7 levels

Age-related body odour

Level 2:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Target odour: Surface-adhered age-related body odour
(3) Test volume: approximately 23 m³-sized test chamber
(4) Test result: Odour intensity reduced by 1.3 levels in 2 hours
(5) Report No.: Y18HM047-1

Level 3:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Target odour: Surface-adhered age-related body odour
(3) Test volume: approximately 23 m³-sized test chamber
(4) Test result: Odour intensity reduced by 1.7 levels in one hour
(5) Report No.: Y18HM059

Level 4 : Effects expected at concentration Level 4

Level 4 is 100 times more concentrated than Level 1, and compared to Level 3 takes less time to realise the effects

Pollen
Time to inhibition of pollen up to 99%

Pollen

Level 3:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 12 hours confirmed
(5) Report No.: L19YA009

Level 4:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered cedar pollen allergens
(3) Test volume: Approx. 24 m³ laboratory (3.64 x 2.73 x 2.4m)
(4) Test Result: Inhibition of 99% or more in 3 hours
(5) Report No.: H21YA017-1

Sweat odour
Deodorisation test

Sweat odour

Level 3:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered sweat odour (hexanoic acid)
(3) Test volume: approx. 23 m³
(4) Test result: Odour intensity was reduced to 1.0 in 2 hours
(5) Report No.: R21HM004-0

Level 4:
(1) Testing organisation: Panasonic Product Analysis Center
(2) Test subject: Adhered sweat odour (hexanoic acid)
(3) Test volume: approx. 23 m³
(4) Test result: Odour intensity was reduced to 3.1 in 2 hours
(5) Report No.: L19YK032-11

For more test results

For more test results

See more evidence

Learn more

See other simulation result by an indoor unit.

Wall-mounted

Wall-mounted

> Mark 1
> Mark 2
> Mark 3

4-way cassette

4-way cassette

> Mark 3

Ceiling

Ceiling

> Mark 2

Adaptive ducted

Adaptive ducted

> Mark 3