$ #,###.00 000 010 //panasonic-newzealand.ibrandiq.com/en/Widgets/FluidPanNZ/{0} //panasonic-newzealand.ibrandiq.com/Products/MultipleInStock/FluidPanNZ/{0}
Photo of S/U-100PT2R5A

S/U-100PT2R5A

Capacity Power source Phase/Hz 1 Phase/ 50Hz
V 230V | 240V
Cooling capacity / Heating capacity kW 10.0 (3.3 - 12.5)
11.2 (4.1 - 14.0)
BTU/h 34,100 (11,300 - 42,700)
38,200 (14,000 - 47,800)
EER : COP Cooling : Heating W/W 3.95 : 4.31
Total power input Cooling : Heating kW 2.53 : 2.60
Indoor Unit Current Cooling : Heating A 0.67 : 0.67 | 0.65 : 0.65
Dimensions H × W × D mm 235×1,590×690
Net weight kg 40
Air Volume Cooling : Heating L/s 500 : 500
Sound pressure level (H/M/L) Cooling : Heating dB(A) 42 / 37 / 35 : 42 / 37 / 35
Sound power level (H/M/L) Cooling : Heating dB(A) 60 / 55 / 53 : 60 / 55 / 53
Number of fan speeds 3
Drain pipe size mm VP-20
Outdoor Unit Current Cooling : Heating A 11.1 : 11.4 | 10.6 : 11.0
Dimensions H × W × D mm 1,416 × 940 × 340
Net weight kg 98
Air Volume Cooling : Heating L/s 1,833: 1,583
Sound pressure level Cooling : Heating dB(A) 52 : 52 ˙
Sound power level Cooling : Heating dB(A) 69 : 69
Piping connections Liquid/Gas m Ø9.52 / Ø15.88
Pipe length min. - max. m 5-75 ˙
Elevation difference (OU located lower, OU located higher) m 15, 30
Maximum chargeless length m 30
Refrigerant at shipping, Additional gas amount g R410A 3,400, 50 (g/m)
Operation ranges Cooling : Heating ˚C -15 to 46 : -20 to 24