Retail Sales Price: Panasonic Online Price: SHOP NOW SHOP NOW WHERE TO BUY Buy from Panasonic Where to Buy Out of Stock at Panasonic Online false false false

Z1 Type Slim Low Static Ducted Twenty Series

Z1 Type Slim Low Static Ducted Twenty Series

Perfectly suited to installations with low ceilings

Z1 Type Slim Low Static Ducted Twenty Series units have a slim design with a height of only 200 mm, making them ideal for small, compact spaces under the ceilings of buildings such as hotels.
  • ECONAVI
  • R410A
Zoom In
Zoom Out
Close
Z1 Type Slim Low Static Ducted Twenty Series

Specs

S-22MZ1H4A

Photo of S-22MZ1H4A

S-28MZ1H4A

Photo of S-28MZ1H4A

S-36MZ1H4A

Photo of S-36MZ1H4A

S-45MZ1H4A

Photo of S-45MZ1H4A

S-56MZ1H4A

Photo of S-56MZ1H4A

S-60MZ1H4A

Photo of S-60MZ1H4A

S-73MZ1H4A

Photo of S-73MZ1H4A
  • ECONAVIECONAVI
  • R410AR410A
  • DC motorDC motor

Ultra-slim profile: 200 mm for all models

DC fan motor greatly reduces power consumption

Ideal for hotel applications with very narrow false ceilings

Easy maintenance and service by an external electrical box

29 Pa static pressure enables ductwork to be fitted

Drain pump (optional)

S-22MZ1H4A S-28MZ1H4A S-36MZ1H4A S-45MZ1H4A S-56MZ1H4A S-60MZ1H4A S-73MZ1H4A
Power Source 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz 220/230/240 V, 1 phase - 50/60 Hz
Cooling Capacity 2.2 kW, 7,500 Btu/h 2.8 kW, 9,500 Btu/h 3.6 kW, 12,200 Btu/h 4.5 kW, 15,300 Btu/h 5.6 kW, 19,100 Btu/h 6.0 kW, 20,500 Btu/h 7.3 kW, 24,900 Btu/h
Heating Capacity 2.5 kW, 8,500 Btu/h 3.2 kW, 10,900 Btu/h 4.2 kW, 14,300 Btu/h 5.1 kW, 17,400 Btu/h 6.4 kW, 21,800 Btu/h 7.1 kW, 24,200 Btu/h 8.0 kW, 27,300 Btu/h
Power Input (Cooling) 0.075/0.075/0.075 kW 0.080/0.080/0.080 kW 0.085/0.085/0.085 kW 0.095/0.095/0.095 kW 0.100/0.100/0.100 kW 0.100/0.100/0.100 kW 0.125/0.125/0.125 kW
Power Input (Heating) 0.075/0.075/0.075 kW 0.080/0.080/0.080 kW 0.085/0.085/0.085 kW 0.095/0.095/0.095 kW 0.100/0.100/0.100 kW 0.100/0.100/0.100 kW 0.125/0.125/0.125 kW
Running Current (Cooling) 0.50/0.47/0.45 A 0.55/0.52/0.50 A 0.60/0.57/0.55 A 0.70/0.68/0.65 A 0.75/0.72/0.70 A 0.75/0.72/0.70 A 0.80/0.78/0.75 A
Running Current (Heating) 0.50/0.47/0.45 A 0.55/0.52/0.50 A 0.60/0.57/0.55 A 0.70/0.68/0.65 A 0.75/0.72/0.70 A 0.75/0.72/0.70 A 0.80/0.78/0.75 A
Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Air Flow Rate (H/M/L) 480/420/360 m³/h, 133/117/100 L/s 600/540/420 m³/h, 167/150/117 L/s 600/540/420 m³/h, 167/150/117 L/s 690/630/510 m³/h, 192/175/142 L/s 720/660/540 m³/h, 200/183/150 L/s 870/750/630 m³/h, 242/208/175 L/s 1,080/840/660 m³/h, 300/233/183 L/s
Fan Motor Output 60 kW 60 kW 60 kW 60 kW 60 kW 60 kW 60 kW
External Static Pressure 10-30 Pa 10-30 Pa 10-30 Pa 10-30 Pa 10-30 Pa 10-30 Pa 10-30 Pa
Sound Power Level (H/M/L) 50/49/47 dB 52/51/49 dB 54/52/50 dB 56/54/52 dB 57/55/53 dB 60/57/55 dB 62/60/58 dB
Sound Pressure Level (H/M/L) 28/27/25 dB (A) 30/29/27 dB (A) 32/30/28 dB (A) 34/32/30 dB (A) 35/33/31 dB (A) 38/35/33 dB (A) 40/38/36 dB (A)
Dimension H200 x W830 x D500 mm H200 x W830 x D500 mm H200 x W830 x D500 mm H200 x W830 x D500 mm H200 x W830 x D500 mm H200 x W830 x D500 mm H200 x W1,050 x D550 mm
Pipe Connection (Liquid) Ø6.35 mm (Ø1/4 inches) Ø6.35 mm (Ø1/4 inches) Ø6.35 mm (Ø1/4 inches) Ø6.35 mm (Ø1/4 inches) Ø6.35 mm (Ø1/4 inches) Ø9.52 mm (Ø3/8 inches) Ø9.52 mm (Ø3/8 inches)
Pipe Connection (Gas) Ø12.7 mm (Ø1/2 inches) Ø12.7 mm (Ø1/2 inches) Ø12.7 mm (Ø1/2 inches) Ø12.7 mm (Ø1/2 inches) Ø12.7 mm (Ø1/2 inches) Ø15.88 mm (Ø5/8 inches) Ø15.88 mm (Ø5/8 inches)
Pipe Connection (Drain Piping) VP-25 VP-25 VP-25 VP-25 VP-25 VP-25 VP-25
Net Weight 17 kg 17 kg 18 kg 18 kg 18 kg 18 kg 24 kg

Documents

Combination

Case Studies

Features

Enables Air Conditioning Without Disturbing Quiet Spaces

Features a low sound pressure level of 25 dB(A)*, as quiet as that of rustling leaves. It is ideal for quiet and relaxing spaces, such as hotel lobbies and guest rooms, thanks to its superior quiet performance.
*For 2.2 kW type and the airflow rate in low mode.
Enables Air Conditioning Without Disturbing Quiet Spaces

ECONAVI Sensor

Providing outstanding energy-saving performance, Panasonic’s inverter VRF System can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of an office. When unnecessary heating or cooling is detected, indoor units are individually controlled to match office conditions for energy-saving operation.

1. Detection of the level of activity enables optimum power saving.
2. Sensor is remotely located to maximise the energy-saving effect.
ECONAVI Sensor

Leading Control Options

Panasonic air conditioning systems allow flexible control options. Individual, centralised, Cloud control and WLAN control are all possible. Please consult with a Panasonic air conditioning specialist for advice as to which control solution best suits your system requirements.
Leading Control Options

Flexible Installation

The Slim Low Static Ducted Twenty Series sits only 200 mm high. This market-leading height enables easy installation into compact ceiling spaces.
Slim & Compact Design

Using the optional high-lift drainage pump, the drain piping rise height can be increased up to 1,000 mm from the drain pipe port.
Note: Optional drainage pump is needed (CZ-73DMZ1).
Drain Pump with Increased Power

An inspection port (450 x 450 mm or more) is required at the lower side of the indoor unit body (field supply).
Installation of Inspection Port Necessary