2-Way Cooling or Heating Mini-FSV LE Series
For small-scale commercial and residential use
The Mini-FSV system LE Series is designed for light commercial and residential use with extraordinary energy-saving performance and a high external static pressure of 35 Pa.
Please Select Your User Type
2-Way Cooling or Heating Mini-FSV LE Series
Specs
- R410A
- Inverter
- Heat Pump
High external static pressure 35 Pa
Wide operation range: Cooling: -10°C to 46°C DB
Refrigerant chargeless up to 50 m (LE2)
Diversity ratio 50-130%
Actual piping length: 150 m (total piping length: 300 m (LE1) / 180 m (LE2))
System difference of elevation: 50 m (outdoor unit above) / 40 m (below)
Documents
Combination
Case Studies
Features
Extraordinary Energy-Saving Performance
The operation efficiency has been improved using a highly efficient R410A refrigerant, a DC Inverter compressor, a DC motor, and a heat exchanger design.
Energy Savings Design
1. Panasonic’s inverter compressor to improve partial-load capacity.
2. 2 pieces of the printed circuit board for easy maintenance.
3. Large-size accumulator to maintain compressor reliability for extended max piping length.
4. DC fan motor for optimum air volume.
5. Newly designed fan blades to inhibit air turbulence and increase efficiency.
6. Redesigned heat exchanger & copper tubes to increase efficiency.
7. Centrifugal oil separator improves oil separation efficiency and reduces refrigerant pressure loss.
2. 2 pieces of the printed circuit board for easy maintenance.
3. Large-size accumulator to maintain compressor reliability for extended max piping length.
4. DC fan motor for optimum air volume.
5. Newly designed fan blades to inhibit air turbulence and increase efficiency.
6. Redesigned heat exchanger & copper tubes to increase efficiency.
7. Centrifugal oil separator improves oil separation efficiency and reduces refrigerant pressure loss.
Variable Evaporation Temperature (VET) for Energy Saving and Comfortable Air conditioning
The indoor and outdoor units work in tandem to control evaporation temperature, refrigerant volume, and airflow. This enables optimal air conditioning according to the number of people in the room and the indoor temperature, as well as energy savings and comfort.
Note: When fan speed is set to Auto.
Demand Response Ready
Simple Demand Response
Featuring inverter control technology, all Panasonic Mini FSV systems are Demand Response Management (DRM) ready. With this control, power consumption at times of peak load can be set in three steps to deliver optimum performance. This helps to reduce annual power consumption with minimal loss in comfort.
Note: Terminal block CZ-CAPDC3 is to be supplied separately.
Flexible Demand Response
The setting is possible as 0% or in the range from 40 to 100% (in steps of 5%). At the time of shipping, the setting has been done to the three steps of 0%, 70%, and 100%.
Note: An outdoor Seri-Para l/O unit CZ-CAPDC2 is to be supplied separately. Demand timer setting for a high-spec remote controller is available.
High Durability
Wide Operating Range
Cooling operation is possible even when the outdoor temperature is as low as -10°C DB or as high as 46°C DB. The remote controller temperature can be set from 18°C up to 30°C*.
*Depending on the type of remote controller.
Note: Note: Cooling capacity depend on indoor/outdoor temperature. Please refer technical databook.
Note: Note: Cooling capacity depend on indoor/outdoor temperature. Please refer technical databook.
Rust-resistant and Easy to Maintain
The anti-corrosion Blue Fin treatment of the heat exchanger provides greater resistance against corrosion. Panasonic also uses a copper tube condenser, which makes it easy to repair and maintain. All models are equipped with Blue Fin condenser.
Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details concerning unit installation and maintenance, please consult an authorised dealer.
Highly Flexible Installation and Design
・ Maximum total piping length 180 m (4/5/6 HP) / 300 m (8/10 HP).
・ Actual piping length 150 m.
・ Elevation difference of maximum 50 m in case of outdoor unit is higher than indoor unit.
・ Maximum 15 meters height difference between indoor units.
・ Up to 50 m of piping without additional gas charging (4/5/6 HP).
・ Up to 13 indoor units connectable in case of 8/10 HP.
・ High external static pressure of 35 Pa.
・ Actual piping length 150 m.
・ Elevation difference of maximum 50 m in case of outdoor unit is higher than indoor unit.
・ Maximum 15 meters height difference between indoor units.
・ Up to 50 m of piping without additional gas charging (4/5/6 HP).
・ Up to 13 indoor units connectable in case of 8/10 HP.
・ High external static pressure of 35 Pa.